Xbox 360:Error Codes: Difference between revisions
(Created page with "Category:Xbox360 {{Warning|DO NOT *EVER* PUT YOUR CONSOLE IN THE FREEZER OR OUT IN COLD/HOT WEATHER OR WRAP IT IN A TOWEL. THESE "FIXES" WILL CAUSE BIGGER PROBLEMS DUE TO...") |
mNo edit summary |
||
Line 29: | Line 29: | ||
====0 Red Lights==== | ====0 Red Lights==== | ||
{| | {| class="wikitable" | ||
| E-Code | |||
| Secondary | |||
| Description | |||
| Fixes | |||
| Detailed Description | |||
|- | |- | ||
| E26 | |||
| 0122 | |||
| CPU/GPU Overheating(Xbox Slim) | | CPU/GPU Overheating(Xbox Slim) | ||
| Apply new thermal paste, make sure heatsink is making good contact with the heat spreader | | Apply new thermal paste, make sure heatsink is making good contact with the heat spreader | ||
| This is the overheating code for the Xbox 360 slim for the CPU/GPU unit. | | This is the overheating code for the Xbox 360 slim for the CPU/GPU unit. | ||
|- | |- | ||
| N/A | |||
| N/A | |||
| No Audio or no Video or both | | No Audio or no Video or both | ||
| X-Clamp Replacement and/or Reflow GPU and HANA chip | | X-Clamp Replacement and/or Reflow GPU and HANA chip | ||
| This error is caused by a cold solder joint in the GPU - HANA chip area, like E74.The 360 doesn’t recognize it yet though. | | This error is caused by a cold solder joint in the GPU - HANA chip area, like E74.The 360 doesn’t recognize it yet though. | ||
|- | |- | ||
| N/A | |||
| N/A | |||
| 360 doesn’t turn on/PSU red light | | 360 doesn’t turn on/PSU red light | ||
| Search the mainboard for shorts/metal chipping/components out of place/etc. X-Clamp replacement(GPU heatsink may be shorting out if too tight) and/or reflow the solder | | Search the mainboard for shorts/metal chipping/components out of place/etc. X-Clamp replacement(GPU heatsink may be shorting out if too tight) and/or reflow the solder | ||
Line 56: | Line 56: | ||
====1 Red Light==== | ====1 Red Light==== | ||
{| | {| class="wikitable" | ||
| E-Code | |||
| Secondary | |||
| Description | |||
| Fixes | |||
| Detailed Description | |||
|- | |- | ||
| E64 | |||
| 1000 | |||
| Bad DVD flash / dead flash chip(Timeout) | | Bad DVD flash / dead flash chip(Timeout) | ||
| Check DVD power and SATA cable for damage and replace if necessary. Make sure any modifications have been installed properly. Flash chip may need desoldering and reflashing with an external progRAMmer, recover DVD key if possible(unless you have backup) | | Check DVD power and SATA cable for damage and replace if necessary. Make sure any modifications have been installed properly. Flash chip may need desoldering and reflashing with an external progRAMmer, recover DVD key if possible(unless you have backup) | ||
| This error occurs if something goes wrong while flashing the drive or installing a modchip. A sign for it is that the DVD drive doesn’t eject the tray anymore. DVD drive timed out during reset. It can also be caused by a faulty DVD power or SATA cable. | | This error occurs if something goes wrong while flashing the drive or installing a modchip. A sign for it is that the DVD drive doesn’t eject the tray anymore. DVD drive timed out during reset. It can also be caused by a faulty DVD power or SATA cable. | ||
|- | |- | ||
| E65 | |||
| 1001 | |||
| Bad DVD flash / dead flash chip (DMA) | | Bad DVD flash / dead flash chip (DMA) | ||
| Ensure all modifications are installed properly. Try to reflash the correct firmware to the drive. The flash chip must be desoldered and reflashed with an external progRAMmer, recover DVD-key if possible(unless you have a backup). | | Ensure all modifications are installed properly. Try to reflash the correct firmware to the drive. The flash chip must be desoldered and reflashed with an external progRAMmer, recover DVD-key if possible(unless you have a backup). | ||
| This error occurs if something goes wrong while flashing the drive or installing a modchip. A sign for it is that the DVD drive can still be flashed and read out. DVD drive is not DMA configured. | | This error occurs if something goes wrong while flashing the drive or installing a modchip. A sign for it is that the DVD drive can still be flashed and read out. DVD drive is not DMA configured. | ||
|- | |- | ||
| E66 | |||
| 1002 | |||
| Wrong DVD drive version | | Wrong DVD drive version | ||
| Reflash the firmware with the correct Vendor version string using your computer. | | Reflash the firmware with the correct Vendor version string using your computer. | ||
| This error occurs when you replace the DVD drive and forget to spoof it with the correct version string of the drive you replaced. | | This error occurs when you replace the DVD drive and forget to spoof it with the correct version string of the drive you replaced. | ||
|- | |- | ||
| E67 | |||
| 1003 | |||
| Broken Hard drive (Timeout) | | Broken Hard drive (Timeout) | ||
| Replace hard drive. Also worth trying Southbridge X-Clamp fix and reflow the Southbridge. | | Replace hard drive. Also worth trying Southbridge X-Clamp fix and reflow the Southbridge. | ||
| This error occurs when your hard drive is defective, it might still work sometimes. Hard drive timed out during reset. There is also a small chance that it is a cold joint under the Southbridge causing problems with the I/O of the HDD. | | This error occurs when your hard drive is defective, it might still work sometimes. Hard drive timed out during reset. There is also a small chance that it is a cold joint under the Southbridge causing problems with the I/O of the HDD. | ||
|- | |- | ||
| E68 | |||
| 1010 | |||
| Broken Hard drive (DMA) | | Broken Hard drive (DMA) | ||
| Replace hard drive. Worth trying Southbridge X-Clamp fix and reflow Southbridge. | | Replace hard drive. Worth trying Southbridge X-Clamp fix and reflow Southbridge. | ||
| If you recently used it with a computer it may have gotten a faulty security sector. This error occurs when your hard drive is defective, it might still work sometimes…. It can also happen because of a bad EEPROM or a wrong security sector.It can also be a problem with the internal connection of the hard drive to the mainboard…Hard drive not DMA configured. | | If you recently used it with a computer it may have gotten a faulty security sector. This error occurs when your hard drive is defective, it might still work sometimes…. It can also happen because of a bad EEPROM or a wrong security sector.It can also be a problem with the internal connection of the hard drive to the mainboard…Hard drive not DMA configured. | ||
|- | |- | ||
| E69 | |||
| 1011 | |||
| Broken Hard drive (HDDSS) | | Broken Hard drive (HDDSS) | ||
| Unplug hard drive and plug back in. Restore HDDSS.bin(hard drive security sector backup). Replace hard drive. | | Unplug hard drive and plug back in. Restore HDDSS.bin(hard drive security sector backup). Replace hard drive. | ||
| This error occurs when your hard drives security sector is unreadable, if you have played around with that make sure to have the correct security sector on the drive…. However it could also just be defective and trigger the error because of that. | | This error occurs when your hard drives security sector is unreadable, if you have played around with that make sure to have the correct security sector on the drive…. However it could also just be defective and trigger the error because of that. | ||
|- | |- | ||
| E70 | |||
| 1012 | |||
| HDD Error Filesystem/Not Found | | HDD Error Filesystem/Not Found | ||
| N/A | | N/A | ||
| HDD Error (Corrupt Filesystem/partitions) or Hard drive not found | | HDD Error (Corrupt Filesystem/partitions) or Hard drive not found | ||
|- | |- | ||
| E71 | |||
| 1013 | |||
| Dashboard update error (NAND related) | | Dashboard update error (NAND related) | ||
| Patch for the fall update / Insert the NXE Update disk before the error screen appears. Reflow Southbridge and Southbridge X-Clamp fix. If software related, JTAG/RGH may be able to fix it. | | Patch for the fall update / Insert the NXE Update disk before the error screen appears. Reflow Southbridge and Southbridge X-Clamp fix. If software related, JTAG/RGH may be able to fix it. | ||
| This error is related to a failed dashboard update, can also be NAND related if you have an Infectus chip…. It can also often be caused by a cold joint under the Southbridge (if it wasn’t caused by an update). Error within Xam | | This error is related to a failed dashboard update, can also be NAND related if you have an Infectus chip…. It can also often be caused by a cold joint under the Southbridge (if it wasn’t caused by an update). Error within Xam | ||
|- | |- | ||
| E72 | |||
| 1020 | |||
| NAND issue (loose pin/ bad flash) | | NAND issue (loose pin/ bad flash) | ||
| Patch for the fall update / Insert the NXE Update disc before the error screen pops up. Reflow Southbridge and Southbridge X-Clamp fix. JTAG/RGH may fix. | | Patch for the fall update / Insert the NXE Update disc before the error screen pops up. Reflow Southbridge and Southbridge X-Clamp fix. JTAG/RGH may fix. | ||
| This error is related to a loose pin or a not existent NAND chip, can also happen if you flashed it badly with an Infectus chip and/or the NAND is dead…. Error within Xam | | This error is related to a loose pin or a not existent NAND chip, can also happen if you flashed it badly with an Infectus chip and/or the NAND is dead…. Error within Xam | ||
|- | |- | ||
| E73 | |||
| 1021 | |||
| Cold solder joint - Ethernet/Southbridge | | Cold solder joint - Ethernet/Southbridge | ||
| Southbridge X-Clamp fix and reflow Southbridge. Check area under Southbridge for parts that may have fallen off/floated out of position and place them back on. Rarely, it can be GPU related, so GPU reflow & X-Clamp fix may help. | | Southbridge X-Clamp fix and reflow Southbridge. Check area under Southbridge for parts that may have fallen off/floated out of position and place them back on. Rarely, it can be GPU related, so GPU reflow & X-Clamp fix may help. | ||
| This error is caused by a cold solder joint under the Southbridge or the ethernet chip. In rare cases it can also be triggered by a cold joint under the GPU on one of the lines that run to the Southbridge chip. Missing parts(caps, resistors…) under the Southbridge can trigger this error as well. | | This error is caused by a cold solder joint under the Southbridge or the ethernet chip. In rare cases it can also be triggered by a cold joint under the GPU on one of the lines that run to the Southbridge chip. Missing parts(caps, resistors…) under the Southbridge can trigger this error as well. | ||
|- | |- | ||
| E74 | |||
| 1022 | |||
| Cold solder joint under GPU- (H)ANA | | Cold solder joint under GPU- (H)ANA | ||
| If you soldered anything to the mainboard before it occurred, whatever you are powering from this point is drawing too much power so get rid of it.Also get rid of everything that you can see that might bridge anything near the GPU. Tighten the GPU screws facing the HANA chip slightly more and make sure to be using a shim. Adding an extra shim on each side of the smaller chip dye will help to create more surface against the heatsink and will increase the chances of the error going away for good. If there is a lot of flexing under the GPU, [https://www.reddit.com/r/360hacks/wiki/360-cooking bake the board] to unflex it. Reflow the GPU and HANA chip. | | If you soldered anything to the mainboard before it occurred, whatever you are powering from this point is drawing too much power so get rid of it.Also get rid of everything that you can see that might bridge anything near the GPU. Tighten the GPU screws facing the HANA chip slightly more and make sure to be using a shim. Adding an extra shim on each side of the smaller chip dye will help to create more surface against the heatsink and will increase the chances of the error going away for good. If there is a lot of flexing under the GPU, [https://www.reddit.com/r/360hacks/wiki/360-cooking bake the board] to unflex it. Reflow the GPU and HANA chip. | ||
| This error is caused by a cold solder joint under the GPU, (H)ANA-chip or in between. Mostly it is one of the outer solder balls on the side facing the (H)ANA chip so a shim increases the chanced of success quite a bit. Can also be a component that is missing or damaged so look for missing parts near the GPU and the (H)ANA chip. | | This error is caused by a cold solder joint under the GPU, (H)ANA-chip or in between. Mostly it is one of the outer solder balls on the side facing the (H)ANA chip so a shim increases the chanced of success quite a bit. Can also be a component that is missing or damaged so look for missing parts near the GPU and the (H)ANA chip. | ||
|- | |- | ||
| E75 | |||
| 1023 | |||
| Network chip cold joint / wrong vendor | | Network chip cold joint / wrong vendor | ||
| Connect the DVD drive and check if the error code is still the same… Remove everything you might have soldered to this area. Reflow the Southbridge and Network chip. Replace the Network chip. | | Connect the DVD drive and check if the error code is still the same… Remove everything you might have soldered to this area. Reflow the Southbridge and Network chip. Replace the Network chip. | ||
| This error is related to the network chip, might be power related or so.This can happen while installing and NME 2. In general it sounds like a cold solder joint somewhere there.However it can also be a Hitachi DVD drive that is not connected… Couldn’t read ethernet phy vendor/wrong ethernet vendor. | | This error is related to the network chip, might be power related or so.This can happen while installing and NME 2. In general it sounds like a cold solder joint somewhere there.However it can also be a Hitachi DVD drive that is not connected… Couldn’t read ethernet phy vendor/wrong ethernet vendor. | ||
|- | |- | ||
| E76 | |||
| 1030 | |||
| Dead network chip | | Dead network chip | ||
| Replace the Network chip. Connect the DVD drive and check if the error code is still the same. Remove everything you might have soldered to this area. Reflow the Southbridge and Network chip. | | Replace the Network chip. Connect the DVD drive and check if the error code is still the same. Remove everything you might have soldered to this area. Reflow the Southbridge and Network chip. | ||
| This error is caused by a dead network chip. This can happen when lightning hits your house and the network chip is under high voltage. Couldn’t complete ethernet reset. | | This error is caused by a dead network chip. This can happen when lightning hits your house and the network chip is under high voltage. Couldn’t complete ethernet reset. | ||
|- | |- | ||
| E77 | |||
| 1031 | |||
| Dead network chip | | Dead network chip | ||
| Replace the Network chip and other damaged components around it like blown capacitors defective regulators etc. Also reflowing Southbridge and Network chip can help | | Replace the Network chip and other damaged components around it like blown capacitors defective regulators etc. Also reflowing Southbridge and Network chip can help | ||
| This error is caused by a dead network chip. It can occur when your house gets hit in a thunderstorm… phy request is already processing/ reading reg failed/ Failed to write reg. | | This error is caused by a dead network chip. It can occur when your house gets hit in a thunderstorm… phy request is already processing/ reading reg failed/ Failed to write reg. | ||
|- | |- | ||
| E78 | |||
| 1032 | |||
| AsicId check failed | | AsicId check failed | ||
| N/A | | N/A | ||
| AsicId check failed | | AsicId check failed | ||
|- | |- | ||
| E79 | |||
| 1033 | |||
| Broken hard drive (Xam.xex) | | Broken hard drive (Xam.xex) | ||
| Replace hard drive. Try Southbridge X-Clamp fix and reflow Southbridge. Check JTAG wiring! Especially the diodes they MUST face the correct direction - Away from J2D2. | | Replace hard drive. Try Southbridge X-Clamp fix and reflow Southbridge. Check JTAG wiring! Especially the diodes they MUST face the correct direction - Away from J2D2. | ||
| This error occurs when your hard drive is defective, it might still work sometimes…. There is also a small chance that it is a cold joint under the Southbridge causing problems with the I/O of the HDD. It can also be related to wiring the diodes while JTAGing. Couldn’t start xam.xex. | | This error occurs when your hard drive is defective, it might still work sometimes…. There is also a small chance that it is a cold joint under the Southbridge causing problems with the I/O of the HDD. It can also be related to wiring the diodes while JTAGing. Couldn’t start xam.xex. | ||
|- | |- | ||
| E80 | |||
| 1100 | |||
| NAND - Wrong LDV Version | | NAND - Wrong LDV Version | ||
| Downgrade to the old dashboard, solder the resistor back on and then update your Xbox. If you have the CPU Key, get the current NAND Flash image and fix the LDV (Just add 1 up to latest kernel). | | Downgrade to the old dashboard, solder the resistor back on and then update your Xbox. If you have the CPU Key, get the current NAND Flash image and fix the LDV (Just add 1 up to latest kernel). | ||
Line 167: | Line 167: | ||
====2 Red Lights==== | ====2 Red Lights==== | ||
{| | {| class="wikitable" | ||
| E-Code | |||
| Secondary | |||
| Description | |||
| Fixes | |||
| Detailed Description | |||
|- | |- | ||
| E05 | |||
| 0011 | |||
| The CPU is overheating | | The CPU is overheating | ||
| Make sure the CPU heatsink is making good contact with the chip, apply a thin layer of compound and put the heatsink on without screws, make sure it gives a good imprint then. Replace CPU X-Clamps, apply new thermal compound. It is possible to cut the temperature sensor trace, but is not recommended. | | Make sure the CPU heatsink is making good contact with the chip, apply a thin layer of compound and put the heatsink on without screws, make sure it gives a good imprint then. Replace CPU X-Clamps, apply new thermal compound. It is possible to cut the temperature sensor trace, but is not recommended. | ||
| This error appears when the CPU overheated, after that the Xbox locks itself until it cooled the chip down. The reason for that is that the heat cant be dissipated to the heatsink/the heatsink isn’t cooled properly… This can be the result of improper thermal compound usage or if the error comes up instantly while booting the console, the heatsink will likely not be making any contact at all with the chip. In rare cases it can also be a faulty temp sensor. | | This error appears when the CPU overheated, after that the Xbox locks itself until it cooled the chip down. The reason for that is that the heat cant be dissipated to the heatsink/the heatsink isn’t cooled properly… This can be the result of improper thermal compound usage or if the error comes up instantly while booting the console, the heatsink will likely not be making any contact at all with the chip. In rare cases it can also be a faulty temp sensor. | ||
|- | |- | ||
| E06 | |||
| 0012 | |||
| The GPU is overheating | | The GPU is overheating | ||
| Make sure the GPU heatsink is making good contact with the chip, apply a thin layer of compound and put the heatsink on without screws, make sure it gives a good imprint then. Replace GPU X-Clamps and apply new thermal compound. It can also be fixed sometimes by just a slight tightening the GPU bolts, (1/4 or 1/8 turn). | | Make sure the GPU heatsink is making good contact with the chip, apply a thin layer of compound and put the heatsink on without screws, make sure it gives a good imprint then. Replace GPU X-Clamps and apply new thermal compound. It can also be fixed sometimes by just a slight tightening the GPU bolts, (1/4 or 1/8 turn). | ||
| This error appears when the GPU overheated, after that the Xbox locks itself until it cooled the chip down. The reason for that is that the heat cant be dissipated to the heatsink/ the heatsink isn’t cooled properly… This can be the result of improper thermal compound usage or if the error comes up instantly while booting the console, the heatsink will likely not be making any contact at all with the chip. | | This error appears when the GPU overheated, after that the Xbox locks itself until it cooled the chip down. The reason for that is that the heat cant be dissipated to the heatsink/ the heatsink isn’t cooled properly… This can be the result of improper thermal compound usage or if the error comes up instantly while booting the console, the heatsink will likely not be making any contact at all with the chip. | ||
|- | |- | ||
| E07 | |||
| 0013 | |||
| Cold joint under RAM/RAM overheating | | Cold joint under RAM/RAM overheating | ||
| Putting the faulty RAM brick under pressure with a 3mm thick craft foam pad. Reflow the RAM chips. A hybrid X-Clamp fix may help. | | Putting the faulty RAM brick under pressure with a 3mm thick craft foam pad. Reflow the RAM chips. A hybrid X-Clamp fix may help. | ||
Line 194: | Line 194: | ||
====2 Red and 2 Green Lights==== | ====2 Red and 2 Green Lights==== | ||
{| | {| class="wikitable" | ||
| E-Code | |||
| Secondary | |||
| Description | |||
| Fixes | |||
| Detailed Description | |||
|- | |- | ||
| E48 | |||
| 0300 | |||
| MFG-Mode: Connection Failed | | MFG-Mode: Connection Failed | ||
| Reflow Southbridge and/or Restore NAND | | Reflow Southbridge and/or Restore NAND | ||
| It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. | | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. | ||
|- | |- | ||
| E49 | |||
| 0301 | |||
| MFG-Mode: Gateway Connect/ NAND Corrupt/Blank | | MFG-Mode: Gateway Connect/ NAND Corrupt/Blank | ||
| Replace RF board, Reflow Southbridge, and/or Restore NAND | | Replace RF board, Reflow Southbridge, and/or Restore NAND | ||
| This error can be caused by a faulty RF board and is indicated by 2 green and 2 red lights which swap every few seconds. It shows that when the console is in manufacturing mode as well, there are rumors that Microsoft does that to modded consoles that were sent in for repairs. It can also occur after an improper NAND update. When the Ethernet cable is connected it also shows E49 on the screen which means that it couldn’t connect to the gateway server in the factory. Single Red Light Takes About 6 Minutes To Show Up. | | This error can be caused by a faulty RF board and is indicated by 2 green and 2 red lights which swap every few seconds. It shows that when the console is in manufacturing mode as well, there are rumors that Microsoft does that to modded consoles that were sent in for repairs. It can also occur after an improper NAND update. When the Ethernet cable is connected it also shows E49 on the screen which means that it couldn’t connect to the gateway server in the factory. Single Red Light Takes About 6 Minutes To Show Up. | ||
|- | |- | ||
| E50 | |||
| 0302 | |||
| MFG-Mode: ConnectX cant be loaded | | MFG-Mode: ConnectX cant be loaded | ||
| Reflow southbridge and/or Restore NAND | | Reflow southbridge and/or Restore NAND | ||
| It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. | | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. | ||
|- | |- | ||
| E51 | |||
| 0303 | |||
| MFG-Mode: Gateway IP not found | | MFG-Mode: Gateway IP not found | ||
| Reflow Southbridge and/or Restore NAND | | Reflow Southbridge and/or Restore NAND | ||
| This error is caused by a problem with the NAND content it might be corrupted and needs to be corrected. This error specifically means that the Console cannot find the IP-address of the Gateway. | | This error is caused by a problem with the NAND content it might be corrupted and needs to be corrected. This error specifically means that the Console cannot find the IP-address of the Gateway. | ||
|- | |- | ||
| E52 | |||
| 0310 | |||
| MFG-Mode: Unable to parse the host response | | MFG-Mode: Unable to parse the host response | ||
| Reflow Southbridge and/or Restore NAND | | Reflow Southbridge and/or Restore NAND | ||
| It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. Could also be problem with Base64 encoding when sending commands. | | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. Could also be problem with Base64 encoding when sending commands. | ||
|- | |- | ||
| E53 | |||
| 0311 | |||
| MFG-Mode: Response submitted (factory command) | | MFG-Mode: Response submitted (factory command) | ||
| Reflow Southbridge and/or Restore NAND | | Reflow Southbridge and/or Restore NAND | ||
| It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. | | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. | ||
|- | |- | ||
| E54 | |||
| 0312 | |||
| MFG-Mode: Problem setting keys | | MFG-Mode: Problem setting keys | ||
| Reflow Southbridge and/or Restore NAND | | Reflow Southbridge and/or Restore NAND | ||
| It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. | | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. | ||
|- | |- | ||
| E55 | |||
| 0313 | |||
| MFG-Mode: Phy Mfgbootlauncher fail? | | MFG-Mode: Phy Mfgbootlauncher fail? | ||
| Reflow Southbridge and/or Restore NAND | | Reflow Southbridge and/or Restore NAND | ||
Line 251: | Line 251: | ||
====3 Red Lights==== | ====3 Red Lights==== | ||
{| | {| class="wikitable" | ||
| E-Code | |||
| Secondary | |||
| Description | |||
| Fixes | |||
| Detailed Description | |||
|- | |- | ||
| E00 | |||
| 0000 | |||
| Xbox freezes after showing the first digit of the error code | | Xbox freezes after showing the first digit of the error code | ||
| Remove the dust from under Southbridge and HANA chip. Reflow Southbridge. X-Clamp replacement. | | Remove the dust from under Southbridge and HANA chip. Reflow Southbridge. X-Clamp replacement. | ||
| The Xbox doesn’t know what’s wrong it freezes after showing the first digit(0) of the error code. Might be a cold solder joint somewhere under the GPU as someone fixed it with the X-Clamp replacement, might also be scaler or Southbridge related since this is where the error code is calculated… It can also be caused by dust under the Southbridge and the HANA chip so please check for that… | | The Xbox doesn’t know what’s wrong it freezes after showing the first digit(0) of the error code. Might be a cold solder joint somewhere under the GPU as someone fixed it with the X-Clamp replacement, might also be scaler or Southbridge related since this is where the error code is calculated… It can also be caused by dust under the Southbridge and the HANA chip so please check for that… | ||
|- | |- | ||
| E01 | |||
| 0001 | |||
| Short circuit in the console/faulty PSU | | Short circuit in the console/faulty PSU | ||
| Make sure your PSU is working and replace it if it isn’t. Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that move out of place while using a heatgun, etc. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU, HANA chip. X-Clamp replacement. | | Make sure your PSU is working and replace it if it isn’t. Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that move out of place while using a heatgun, etc. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU, HANA chip. X-Clamp replacement. | ||
| This error can be triggered by a faulty power supply or a short in the console. The short is located near one of the main supply lines, so mostly not under the chips, it might also be a blown capacitor fuse or just a bridged contact. Also damaged DVD power cable. The GPU heatsink might be shorting out if you screwed it in too tight. | | This error can be triggered by a faulty power supply or a short in the console. The short is located near one of the main supply lines, so mostly not under the chips, it might also be a blown capacitor fuse or just a bridged contact. Also damaged DVD power cable. The GPU heatsink might be shorting out if you screwed it in too tight. | ||
|- | |- | ||
| E02 | |||
| 0002 | |||
| Cold solder joint under CPU | | Cold solder joint under CPU | ||
| Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that moved out of place while reflowing, etc. - Especially in the CPU area. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU. X-Clamp replacement. | | Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that moved out of place while reflowing, etc. - Especially in the CPU area. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU. X-Clamp replacement. | ||
| This error code is caused by a cold solder joint under the CPU or by a problem with the way it is powered(blown MOSFET, capacitor or a short). It may also be a problem with the ethernet chip but there aren’t any references for that. | | This error code is caused by a cold solder joint under the CPU or by a problem with the way it is powered(blown MOSFET, capacitor or a short). It may also be a problem with the ethernet chip but there aren’t any references for that. | ||
|- | |- | ||
| E03 | |||
| 0003 | |||
| Power problem/ Cold solder joint under CPU | | Power problem/ Cold solder joint under CPU | ||
| Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that moved out of place while reflowing, etc. - Especially in the CPU area. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU. X-Clamp replacement. | | Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that moved out of place while reflowing, etc. - Especially in the CPU area. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU. X-Clamp replacement. | ||
| The CPU is somehow not getting clean power, can be a cold solder joint under it or one of the external parts like a missing cap etc. | | The CPU is somehow not getting clean power, can be a cold solder joint under it or one of the external parts like a missing cap etc. | ||
|- | |- | ||
| E04 | |||
| 0010 | |||
| Cold solder joint under Southbridge OR bad RF board | | Cold solder joint under Southbridge OR bad RF board | ||
| Try another RF board. If LEDs were modded, try removing them. Southbridge X-Clamp replacement. Southbridge reflow. Check the are under the Southbridge for parts that might have fallen off and solder them back on. | | Try another RF board. If LEDs were modded, try removing them. Southbridge X-Clamp replacement. Southbridge reflow. Check the are under the Southbridge for parts that might have fallen off and solder them back on. | ||
| There is a problem with the Southbridge Chip usually dealing with how it connects to the mainboard (cold solder joint/bridged solder joints)(Taken from Xbox-Scene) | | There is a problem with the Southbridge Chip usually dealing with how it connects to the mainboard (cold solder joint/bridged solder joints)(Taken from Xbox-Scene) | ||
|- | |- | ||
| E08 | |||
| 0020 | |||
| Bridged solder joint/short - CPU/GPU/RAM | | Bridged solder joint/short - CPU/GPU/RAM | ||
| If you worked on the mainboard recently(soldered or so) remove these wires because you might be drawing too much power from the GPU. Also look for missing/bridged components like capacitors/resistors. If you JTAG hacked the console, remove wires and resistors, the parallel port can stay as long as no PC is connected. X-Clamp replacement. Flush with alcohol, let dry, begin reflow with flux like below. Reflow GPU and RAM area. Reball GPU and RAM for bridged solder. | | If you worked on the mainboard recently(soldered or so) remove these wires because you might be drawing too much power from the GPU. Also look for missing/bridged components like capacitors/resistors. If you JTAG hacked the console, remove wires and resistors, the parallel port can stay as long as no PC is connected. X-Clamp replacement. Flush with alcohol, let dry, begin reflow with flux like below. Reflow GPU and RAM area. Reball GPU and RAM for bridged solder. | ||
| This error is caused by a bridged solder joint under CPU, GPU or one of the RAM bricks. This effect can also be caused by tin whiskers leading to shorts and if the GPU was taken off the mainboard this error will also show up. It can also be power related(the CPU/GPU or RAM isn’t getting enough power). Can also be a component that is missing or damaged so look for missing and bridged parts near the GPU. If the console was JTAGged and the resistors and cables are still connected it will show 0020, the parallel port can stay as long as no PC is connected. | | This error is caused by a bridged solder joint under CPU, GPU or one of the RAM bricks. This effect can also be caused by tin whiskers leading to shorts and if the GPU was taken off the mainboard this error will also show up. It can also be power related(the CPU/GPU or RAM isn’t getting enough power). Can also be a component that is missing or damaged so look for missing and bridged parts near the GPU. If the console was JTAGged and the resistors and cables are still connected it will show 0020, the parallel port can stay as long as no PC is connected. | ||
|- | |- | ||
| E09 | |||
| 0021 | |||
| Bridged solder joint/Short - GPU/Southbridge | | Bridged solder joint/Short - GPU/Southbridge | ||
| If you worked on the mainboard recently(soldered or so) remove these wires because you might be drawing too much power from the Southbridge. Also look for missing/bridged components like capacitors/resistors. X-Clamp replacement. Southbridge X-Clamp fix. Reflow Southbridge/Ethernet chip area. Reball the Southbridge - bridged solder. If you work in dumping lite-on 8xxxx and 9xxxx with jumper, Check your DVD drive motherboard again, if there’s still some shorting. Wrong GPU model (e.g. Zephyr/Falcon GPU reballed onto a Xenon board). | | If you worked on the mainboard recently(soldered or so) remove these wires because you might be drawing too much power from the Southbridge. Also look for missing/bridged components like capacitors/resistors. X-Clamp replacement. Southbridge X-Clamp fix. Reflow Southbridge/Ethernet chip area. Reball the Southbridge - bridged solder. If you work in dumping lite-on 8xxxx and 9xxxx with jumper, Check your DVD drive motherboard again, if there’s still some shorting. Wrong GPU model (e.g. Zephyr/Falcon GPU reballed onto a Xenon board). | ||
| This error is caused by a bridged solder joint under GPU or Southbridge. It can also be power related(the Southbridge isn’t getting enough power). Can also be a component that is missing or damaged so look for missing and bridged parts(caps etc) near the Southbridge. | | This error is caused by a bridged solder joint under GPU or Southbridge. It can also be power related(the Southbridge isn’t getting enough power). Can also be a component that is missing or damaged so look for missing and bridged parts(caps etc) near the Southbridge. | ||
|- | |- | ||
| E10 | |||
| 0022 | |||
| Bridged solder joint/Short GPU-> (H)ANA | | Bridged solder joint/Short GPU-> (H)ANA | ||
| If you soldered anything to the mainboard before it occurred, whatever you are powering from this point is drawing too much power so get rid of it.Also get rid of everything that you can see that might bridge anything near the GPU. X-Clamp replacement. Reflow GPU and HANA chip. Reflow GPU and HANA chip. Reflow CPU. If using JTAG on JTAG-fixed Xbox 360 this will appear, flash to original NAND. Can be caused by broken trace. | | If you soldered anything to the mainboard before it occurred, whatever you are powering from this point is drawing too much power so get rid of it.Also get rid of everything that you can see that might bridge anything near the GPU. X-Clamp replacement. Reflow GPU and HANA chip. Reflow GPU and HANA chip. Reflow CPU. If using JTAG on JTAG-fixed Xbox 360 this will appear, flash to original NAND. Can be caused by broken trace. | ||
| This error is caused by a bridged/shorting solder joint under the GPU, (H)ANA-chip or in between. It can also be power related though, for example if you are drawing power from one of the regulators that power the GPU and HANA-chip. Can also be a component that is missing or damaged so look for missing parts near the GPU and the HANA chip. In extremely rare cases it might also be related to the lines that lead from HANA to the CPU. The chances are however higher that it is the GPU than the HANA chip so you should always first concentrate on the GPU. Another cause could be due to a broken trace under the board near one of the RAM blocks ([https://i.imgur.com/z06x9Ag.jpg picture]). This error also shows up if the CPU was taken off the mainboard. | | This error is caused by a bridged/shorting solder joint under the GPU, (H)ANA-chip or in between. It can also be power related though, for example if you are drawing power from one of the regulators that power the GPU and HANA-chip. Can also be a component that is missing or damaged so look for missing parts near the GPU and the HANA chip. In extremely rare cases it might also be related to the lines that lead from HANA to the CPU. The chances are however higher that it is the GPU than the HANA chip so you should always first concentrate on the GPU. Another cause could be due to a broken trace under the board near one of the RAM blocks ([https://i.imgur.com/z06x9Ag.jpg picture]). This error also shows up if the CPU was taken off the mainboard. | ||
|- | |- | ||
| E11 | |||
| 0023 | |||
| (unknown) probably a short under Southbridge>ANA | | (unknown) probably a short under Southbridge>ANA | ||
| N/A | | N/A | ||
| This error is unknown but assumed to be a short either under Southbridge and (H)ANA chip or in between these. Look for 0021 and 0022 and reflow the Southbridge-> HANA chip area, the X-Clamp Fix might help as well. | | This error is unknown but assumed to be a short either under Southbridge and (H)ANA chip or in between these. Look for 0021 and 0022 and reflow the Southbridge-> HANA chip area, the X-Clamp Fix might help as well. | ||
|- | |- | ||
| E12 | |||
| 0030 | |||
| Temp sensor problem/ Cold solder joint under CPU | | Temp sensor problem/ Cold solder joint under CPU | ||
| Replace X-Clamps. Reflow CPU. Cut CPU temp sensor trace (NOT RECOMMENDED!) | | Replace X-Clamps. Reflow CPU. Cut CPU temp sensor trace (NOT RECOMMENDED!) | ||
| The temp sensor is not working properly, maybe because it is shorting out (2 bridged solder balls). If it’s completely broken, you may need to cut the trace anyway. | | The temp sensor is not working properly, maybe because it is shorting out (2 bridged solder balls). If it’s completely broken, you may need to cut the trace anyway. | ||
|- | |- | ||
| E13 | |||
| 0031 | |||
| Faulty RAM brick/ Shorted out resistor | | Faulty RAM brick/ Shorted out resistor | ||
| Reflow RAM and Southbridge. Loosen heatsink screws and make sure heatsink isn’t shorting out a capacitor. Replace faulty RAM brick. X-Clamp replacement. Replace DVD power cord. Unbridged U6T1 or U6T2(points that protect CPU-fuse) | | Reflow RAM and Southbridge. Loosen heatsink screws and make sure heatsink isn’t shorting out a capacitor. Replace faulty RAM brick. X-Clamp replacement. Replace DVD power cord. Unbridged U6T1 or U6T2(points that protect CPU-fuse) | ||
| This error is caused by a faulty/cracked RAM brick, however it can also be caused when the heatsink is shorting out a resistor or like a bad solder joint under the GPU?, check out the links in the references… Also caused by the Southbridge if not properly soldered to motherboard or if it experiences a power short. Can be caused by a backwards power cord or faulty power cord to DVD player. If you update to freeboot 9199 with bridged U6T1 or U6T2 this error will appear, unbridged it. | | This error is caused by a faulty/cracked RAM brick, however it can also be caused when the heatsink is shorting out a resistor or like a bad solder joint under the GPU?, check out the links in the references… Also caused by the Southbridge if not properly soldered to motherboard or if it experiences a power short. Can be caused by a backwards power cord or faulty power cord to DVD player. If you update to freeboot 9199 with bridged U6T1 or U6T2 this error will appear, unbridged it. | ||
|- | |- | ||
| E14 | |||
| 0032 | |||
| (unknown) probably temp sensor related | | (unknown) probably temp sensor related | ||
| N/A | | N/A | ||
| Might be temp sensor related, check out 0030 | | Might be temp sensor related, check out 0030 | ||
|- | |- | ||
| E15 | |||
| 0033 | |||
| (unknown) probably temp sensor related | | (unknown) probably temp sensor related | ||
| N/A | | N/A | ||
| Might be temp sensor related, check out 0030 | | Might be temp sensor related, check out 0030 | ||
|- | |- | ||
| E16 | |||
| 0100 | |||
| Cold solder joint - GPU | | Cold solder joint - GPU | ||
| X-Clamp Replacement. Reflow GPU. | | X-Clamp Replacement. Reflow GPU. | ||
| This error is a Cold solder joint under the GPU just like 0102, can be fixed with the X-Clamp replacement. | | This error is a Cold solder joint under the GPU just like 0102, can be fixed with the X-Clamp replacement. | ||
|- | |- | ||
| E17 | |||
| 0101 | |||
| USB port (bridged pins) | | USB port (bridged pins) | ||
| Unplug all USB devices that might be connected to your 360. Remove solder from the pins under the USB ports so that they are not shorting out anymore, also check the ports themselves and make sure that the pins inside aren’t bridging. | | Unplug all USB devices that might be connected to your 360. Remove solder from the pins under the USB ports so that they are not shorting out anymore, also check the ports themselves and make sure that the pins inside aren’t bridging. | ||
| This error is caused by bridged solder joints under the USB ports or a defective USB device that is connected to it. | | This error is caused by bridged solder joints under the USB ports or a defective USB device that is connected to it. | ||
|- | |- | ||
| E18 | |||
| 0102 | |||
| Cold solder joint - CPU/GPU/RAM | | Cold solder joint - CPU/GPU/RAM | ||
| X-Clamp replacement. Reflow GPU and RAM. | | X-Clamp replacement. Reflow GPU and RAM. | ||
| This error is caused by a cold solder joint under CPU, GPU or one of the RAM bricks. Can also be a component that is missing or damaged so look for missing parts near the GPU. | | This error is caused by a cold solder joint under CPU, GPU or one of the RAM bricks. Can also be a component that is missing or damaged so look for missing parts near the GPU. | ||
|- | |- | ||
| E19 | |||
| 0103 | |||
| Cold solder joint- GPU/ bad cap | | Cold solder joint- GPU/ bad cap | ||
| Remove short circuit from bridged capacitor under the GPU. X-Clamp replacement. Reflow CPU/GPU/RAM. | | Remove short circuit from bridged capacitor under the GPU. X-Clamp replacement. Reflow CPU/GPU/RAM. | ||
| This error can either be caused by a cold solder joint under the GPU or a bridged capacitor under it(power problem). | | This error can either be caused by a cold solder joint under the GPU or a bridged capacitor under it(power problem). | ||
|- | |- | ||
| E20 | |||
| 0110 | |||
| Cold solder joint -> RAM | | Cold solder joint -> RAM | ||
| Reflow the RAM. Loosen your heatsink screws and make sure the heatsink isn’t shorting out a capacitor. Look for missing and bridged components like resisitors and caps and replace them. X-Clamp replacement. | | Reflow the RAM. Loosen your heatsink screws and make sure the heatsink isn’t shorting out a capacitor. Look for missing and bridged components like resisitors and caps and replace them. X-Clamp replacement. | ||
| This error is caused by a cold solder joint under one of the RAM chips, mostly its the top ones, sometimes it can also be one of the solder balls under the GPU that lead to the RAM. It can also be cause by a broken trace that connects the GPU and the RAM, the reason for it to break could be the flexing in this certain area. | | This error is caused by a cold solder joint under one of the RAM chips, mostly its the top ones, sometimes it can also be one of the solder balls under the GPU that lead to the RAM. It can also be cause by a broken trace that connects the GPU and the RAM, the reason for it to break could be the flexing in this certain area. | ||
|- | |- | ||
| E21 | |||
| 0111 | |||
| (unknown) probably NAND/RAM? | | (unknown) probably NAND/RAM? | ||
| N/A | | N/A | ||
| This error is unknown but could be somehow related to a cold solder joint under the RAM.On Xbox-scene there was also a post in which was claimed that it has to do with the NAND. | | This error is unknown but could be somehow related to a cold solder joint under the RAM.On Xbox-scene there was also a post in which was claimed that it has to do with the NAND. | ||
|- | |- | ||
| E22 | |||
| 0112 | |||
| (unknown) probably RAM | | (unknown) probably RAM | ||
| N/A | | N/A | ||
| This error is totally unknown, probably it is RAM related like 0110. | | This error is totally unknown, probably it is RAM related like 0110. | ||
|- | |- | ||
| E23 | |||
| 0113 | |||
| (unknown) probably RAM | | (unknown) probably RAM | ||
| N/A | | N/A | ||
| This error is totally unknown, probably it is RAM related like 0110. | | This error is totally unknown, probably it is RAM related like 0110. | ||
|- | |- | ||
| E24 | |||
| 0120 | |||
| (unknown) short under RAM | | (unknown) short under RAM | ||
| Penny fix on RAM | | Penny fix on RAM | ||
| This error is unknown but someone on Xbox-scene could fix it using the penny fix.Could be a short in the area under the RAM that causes 0110 when there is a cold solder joint. If it was like usual the error code would be 0020. | | This error is unknown but someone on Xbox-scene could fix it using the penny fix.Could be a short in the area under the RAM that causes 0110 when there is a cold solder joint. If it was like usual the error code would be 0020. | ||
|- | |- | ||
| E25 | |||
| 0121 | |||
| Cold solder joint under CPU | | Cold solder joint under CPU | ||
| Replacing the X-Clamps. Reflowing CPU. | | Replacing the X-Clamps. Reflowing CPU. | ||
| Cold solder joint under CPU. The CPU cant communicate with the mainboard. | | Cold solder joint under CPU. The CPU cant communicate with the mainboard. | ||
|- | |- | ||
| E27 | |||
| 0123 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| The error is completely unknown | | The error is completely unknown | ||
|- | |- | ||
| E28 | |||
| 0130 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| The error is completely unknown | | The error is completely unknown | ||
|- | |- | ||
| E29 | |||
| 0131 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| The error is completely unknown | | The error is completely unknown | ||
|- | |- | ||
| E30 | |||
| 0132 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| The error is completely unknown | | The error is completely unknown | ||
|- | |- | ||
| E31 | |||
| 0133 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| The error is completely unknown | | The error is completely unknown | ||
|- | |- | ||
| E32 | |||
| 0200 | |||
| Cold solder joint GPU/RAM | | Cold solder joint GPU/RAM | ||
| Reflow the GPU/RAM and flush them with alcohol. X-Clamp Fix. | | Reflow the GPU/RAM and flush them with alcohol. X-Clamp Fix. | ||
| This error is caused by a Cold Joint in the GPU/RAM area similar to 0102 good results could be achieved with flushing alcohol under the chips, reflowing them and afterwards applying an X-Clamp Fix. | | This error is caused by a Cold Joint in the GPU/RAM area similar to 0102 good results could be achieved with flushing alcohol under the chips, reflowing them and afterwards applying an X-Clamp Fix. | ||
|- | |- | ||
| E33 | |||
| 0201 | |||
| Cold solder joint-> GPU/RAM | | Cold solder joint-> GPU/RAM | ||
| N/A | | N/A | ||
| The error is very rare but it is somehow GPU/RAM related, two people could fix it with the Improved X-Clamp replacement, one had to remove his washers from the RAM in order to get it to work. | | The error is very rare but it is somehow GPU/RAM related, two people could fix it with the Improved X-Clamp replacement, one had to remove his washers from the RAM in order to get it to work. | ||
|- | |- | ||
| E34 | |||
| 0202 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| The error is completely unknown | | The error is completely unknown | ||
|- | |- | ||
| E35 | |||
| 0203 | |||
| GPU related - resistors | | GPU related - resistors | ||
| N/A | | N/A | ||
| code 0203 - instant RROD every time. chip malfunction, not getting a connection to the board (not an overheating problem but a bad contact problem) mine turned out to be broken prongs in a corner on the GPU, missing 3 of them. didn’t see this until i was comparing with another board. i believe these are mini resistors on the bottom side of the chip due to mistreatment. | | code 0203 - instant RROD every time. chip malfunction, not getting a connection to the board (not an overheating problem but a bad contact problem) mine turned out to be broken prongs in a corner on the GPU, missing 3 of them. didn’t see this until i was comparing with another board. i believe these are mini resistors on the bottom side of the chip due to mistreatment. | ||
|- | |- | ||
| E36 | |||
| 0210 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown | | This error is completely unknown | ||
|- | |- | ||
| E37 | |||
| 0211 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown | | This error is completely unknown | ||
|- | |- | ||
| E38 | |||
| 0212 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown | | This error is completely unknown | ||
|- | |- | ||
| E39 | |||
| 0213 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown | | This error is completely unknown | ||
|- | |- | ||
| E40 | |||
| 0220 | |||
| (unknown) missing resistors GPU | | (unknown) missing resistors GPU | ||
| N/A | | N/A | ||
| This error is unknown but is assumed to be caused by missing resistors, probably on GPU. | | This error is unknown but is assumed to be caused by missing resistors, probably on GPU. | ||
|- | |- | ||
| E41 | |||
| 0221 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E42 | |||
| 0222 | |||
| (unknown) GPU/CPU related? | | (unknown) GPU/CPU related? | ||
| X-Clamp replacement. | | X-Clamp replacement. | ||
| This error is unknown but someone managed to fix it using the X-Clamp replacement. | | This error is unknown but someone managed to fix it using the X-Clamp replacement. | ||
|- | |- | ||
| E43 | |||
| 0223 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E44 | |||
| 0230 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E45 | |||
| 0231 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E46 | |||
| 0232 | |||
| DVD Drive Failure | | DVD Drive Failure | ||
| Fixed by Microsoft (unconfirmed) | | Fixed by Microsoft (unconfirmed) | ||
| “The DVD drive overheats. This error can be caused by the disconnecting of the DVD drive. This is usually not the case.” (unconfirmed) | | “The DVD drive overheats. This error can be caused by the disconnecting of the DVD drive. This is usually not the case.” (unconfirmed) | ||
|- | |- | ||
| E47 | |||
| 0233 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E56 | |||
| 0320 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E57 | |||
| 0321 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E58 | |||
| 0322 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E59 | |||
| 0323 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E60 | |||
| 0330 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E61 | |||
| 0331 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E62 | |||
| 0332 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
| This error is completely unknown. | | This error is completely unknown. | ||
|- | |- | ||
| E63 | |||
| 0333 | |||
| (unknown) | | (unknown) | ||
| N/A | | N/A | ||
Line 572: | Line 572: | ||
====4 Red Lights==== | ====4 Red Lights==== | ||
{| | {| class="wikitable" | ||
| E-Code | |||
| Secondary | |||
! Description | ! Description | ||
! Fixes | ! Fixes | ||
! Detailed Description | ! Detailed Description | ||
|- | |- | ||
| N/A | |||
| 4444 | |||
| Faulty/Missing A/V cable or (H)ANA related | | Faulty/Missing A/V cable or (H)ANA related | ||
| N/A | | N/A | ||
Line 604: | Line 604: | ||
You should be able to determine the difference between the 3 flashing lights and the error code lights by the rate in which they flash. | You should be able to determine the difference between the 3 flashing lights and the error code lights by the rate in which they flash. | ||
{| | {| class="wikitable" | ||
! Number of Lights Flashing | ! Number of Lights Flashing | ||
! Error Digit | ! Error Digit |
Revision as of 18:49, 26 May 2021
DO NOT *EVER* PUT YOUR CONSOLE IN THE FREEZER OR OUT IN COLD/HOT WEATHER OR WRAP IT IN A TOWEL. THESE "FIXES" WILL CAUSE BIGGER PROBLEMS DUE TO TEMPERATURE SHOCK, BOARD WARPING, CONDENSATION, AND OVERHEATING. BETTER FIXES CAN BE FOUND ON THIS PAGE. |
This page is intended to be a comprehensive list of all error codes for all models of Xbox 360, as well as tutorials on fixing them if applicable/possible. This error code guide is in no way official and may not be 100% accurate as it is community sourced. If you discover something that is incorrect or not included please message the moderators to have it updated. We take no responsibility for any actions you may take to fix your console.
Generally, if there is a problem with the Xbox 360, the LEDs in the Ring of Light (ROL) around the power button will flash in a particular pattern. The pattern itself lends some insight to the problem. Certain patterns will also display numbered error codes on screen, known as your primary error code, which will further help diagnose your console’s issue.
Officially documented descriptions of the errors can be found on Octal’s RROD Database (officially documented errors).
Ring of Light Error Codes
Determining the malfunctioning component of your Xbox 360 depends on how many red lights around the power button are flashing.
One Red Light
If the bottom right red light is flashing on your Xbox 360, then your console is experiencing a hardware error. The console will still power on, and should display an error code on the screen it is connected to. The code will begin with an E, followed by two digits. Some in-depth error code information can be found on this page below. The Specific Type of hardware failure can be determined by the error code displayed on the screen. If the screen is blank or you would like additional information follow the instructions for determining the secondary error code in the section for it below.
Two Red Lights
When the left two lights are flashing red on the console, a component is overheating. It is likely that the fan will be running very loudly. Shut the console off and let it cool down for a couple hours. To prevent this from happening in the future, make sure your Xbox 360 is in a well-ventilated area and out of the immediate proximity of any walls, heaters, or other appliances. Alternatively Overheating can be cause by the console locking up or “freezing” after a set amount of time. Lockups that occur at a specific point in a game are generally problems with the game itself and not caused by overheating. Let the Xbox 360 console cool. You may have to wait several hours for the console to cool enough. Do not turn on the console when the console is hot. Verify that the console has sufficient ventilation and that the fan is operating. For more information about ventilation, see the Care page. To try to prevent this problem, use the following precautions: Do not block any ventilation openings on the Xbox 360 console, Do not put the Xbox 360 console on a bed, on a sofa, or on any other soft surface that may block ventilation openings, Do not put the Xbox 360 console in a confined space, such as a bookcase, a rack, or a stereo cabinet, unless the space is well-ventilated, Do not put the Xbox 360 console near any heat source, such as a radiator, a heat register, a stove, or an amplifier.
Three Red Lights (“Red Ring of Death”)
The “Red Ring of Death” has occurred when all but the top right corner of the light ring are flashing red. A general hardware malfunction has occurred, affecting one or more components. The error message is not displayed directly, since the console doesn’t power on, but it is possible to obtain the secondary error code from the Xbox. Most, if not all, three-light errors in Xbox 360 consoles are related to overheating. The most common issue is a cracked or cold solder joint underneath the GPU on the motherboard. A flaw in the design of the heat sink allows the motherboard to warp in the area around the chip, which causes the chip to lose contact with the board. There are various fixes for the RROD, which include replacing the high-stress x-clamp, reflowing the GPU’s solder connection, and also replacing the heat sink in older models with Microsoft’s updated Zephyr heat sink. To keep your Xbox 360 from being affected by the RROD, keep it in a well-ventilated area and make sure the cooling vents are free from obstruction. If your Xbox begins to overheat, turn the power off and allow it to cool for at least an hour before continuing play. Alternatively, use an external fan to help circulate air across the device. If the RROD is already plaguing your Xbox, and your console is no longer covered by Microsoft’s warranty, there is hope yet. Even though the console will not turn on, you can obtain a secondary error code from it. After pinpointing the cause of your Xbox’s RROD, you can take the necessary action to remove the problem. Red Ring errors caused by the CPU or GPU are normally fixed by installing a Red Ring of Death Fix Kit. Try restarting the console. If restarting the console does not resolve the behavior, follow these steps: Turn the console off, Unplug all the power and AV cables from the console, Unplug the power cord from the wall socket, Firmly reconnect all the cables, Turn on the console. If these steps do not resolve the behavior, turn the console off, remove the hard drive, and then turn on the console. If the 3x Red LED error light is no longer displayed, turn the console off, re-attach the hard drive, and then turn on the console. Also examine the lights on the power supply. When you turn on the console, the power supply light should illuminate green even if the three lights on the ROL flash red.
Four Red Lights Flashing
The Xbox 360 A/V cable is not connected. Make sure that the AV cable is correctly connected to the Xbox 360 console. Reconnect the cable either to the console or the display you are using. Disconnect the AV cable from the Xbox 360 console, and then reconnect the AV cable to the Xbox 360 console. If the four flashing red lights continue to flash, try wiping the metal area of the AV pack with a dry cloth. The metal area is the end that plugs into the console. Wipe the metal area thoroughly, and then try the AV Pack again. If the AV cable is correctly connected but the four red lights are still flashing, substitute a different AV cable if you have one available.
Manufacture Mode (Xmas Lights)
Sections 1, 2, 3, and 4 are flashing red and green. If you attempted the JTAG hack, restore your original NAND image and/or reflow the Southbridge. Be aware that Xenon keyvaults have a Type 1 keyvault, while all other Xbox 360s have a Type 2 keyvault. Either type can be used on a Xenon, but a Type 1 keyvault cannot be used on a newer console or else you will get this error.
Primary Error Codes
0 Red Lights
E-Code | Secondary | Description | Fixes | Detailed Description |
E26 | 0122 | CPU/GPU Overheating(Xbox Slim) | Apply new thermal paste, make sure heatsink is making good contact with the heat spreader | This is the overheating code for the Xbox 360 slim for the CPU/GPU unit. |
N/A | N/A | No Audio or no Video or both | X-Clamp Replacement and/or Reflow GPU and HANA chip | This error is caused by a cold solder joint in the GPU - HANA chip area, like E74.The 360 doesn’t recognize it yet though. |
N/A | N/A | 360 doesn’t turn on/PSU red light | Search the mainboard for shorts/metal chipping/components out of place/etc. X-Clamp replacement(GPU heatsink may be shorting out if too tight) and/or reflow the solder | This error can be triggered by a faulty power supply or a short in the console.The short is located near one of the main supply lines, so not under the chips, it might also be a blown capacitor fuse or just a bridged contact. |
1 Red Light
E-Code | Secondary | Description | Fixes | Detailed Description |
E64 | 1000 | Bad DVD flash / dead flash chip(Timeout) | Check DVD power and SATA cable for damage and replace if necessary. Make sure any modifications have been installed properly. Flash chip may need desoldering and reflashing with an external progRAMmer, recover DVD key if possible(unless you have backup) | This error occurs if something goes wrong while flashing the drive or installing a modchip. A sign for it is that the DVD drive doesn’t eject the tray anymore. DVD drive timed out during reset. It can also be caused by a faulty DVD power or SATA cable. |
E65 | 1001 | Bad DVD flash / dead flash chip (DMA) | Ensure all modifications are installed properly. Try to reflash the correct firmware to the drive. The flash chip must be desoldered and reflashed with an external progRAMmer, recover DVD-key if possible(unless you have a backup). | This error occurs if something goes wrong while flashing the drive or installing a modchip. A sign for it is that the DVD drive can still be flashed and read out. DVD drive is not DMA configured. |
E66 | 1002 | Wrong DVD drive version | Reflash the firmware with the correct Vendor version string using your computer. | This error occurs when you replace the DVD drive and forget to spoof it with the correct version string of the drive you replaced. |
E67 | 1003 | Broken Hard drive (Timeout) | Replace hard drive. Also worth trying Southbridge X-Clamp fix and reflow the Southbridge. | This error occurs when your hard drive is defective, it might still work sometimes. Hard drive timed out during reset. There is also a small chance that it is a cold joint under the Southbridge causing problems with the I/O of the HDD. |
E68 | 1010 | Broken Hard drive (DMA) | Replace hard drive. Worth trying Southbridge X-Clamp fix and reflow Southbridge. | If you recently used it with a computer it may have gotten a faulty security sector. This error occurs when your hard drive is defective, it might still work sometimes…. It can also happen because of a bad EEPROM or a wrong security sector.It can also be a problem with the internal connection of the hard drive to the mainboard…Hard drive not DMA configured. |
E69 | 1011 | Broken Hard drive (HDDSS) | Unplug hard drive and plug back in. Restore HDDSS.bin(hard drive security sector backup). Replace hard drive. | This error occurs when your hard drives security sector is unreadable, if you have played around with that make sure to have the correct security sector on the drive…. However it could also just be defective and trigger the error because of that. |
E70 | 1012 | HDD Error Filesystem/Not Found | N/A | HDD Error (Corrupt Filesystem/partitions) or Hard drive not found |
E71 | 1013 | Dashboard update error (NAND related) | Patch for the fall update / Insert the NXE Update disk before the error screen appears. Reflow Southbridge and Southbridge X-Clamp fix. If software related, JTAG/RGH may be able to fix it. | This error is related to a failed dashboard update, can also be NAND related if you have an Infectus chip…. It can also often be caused by a cold joint under the Southbridge (if it wasn’t caused by an update). Error within Xam |
E72 | 1020 | NAND issue (loose pin/ bad flash) | Patch for the fall update / Insert the NXE Update disc before the error screen pops up. Reflow Southbridge and Southbridge X-Clamp fix. JTAG/RGH may fix. | This error is related to a loose pin or a not existent NAND chip, can also happen if you flashed it badly with an Infectus chip and/or the NAND is dead…. Error within Xam |
E73 | 1021 | Cold solder joint - Ethernet/Southbridge | Southbridge X-Clamp fix and reflow Southbridge. Check area under Southbridge for parts that may have fallen off/floated out of position and place them back on. Rarely, it can be GPU related, so GPU reflow & X-Clamp fix may help. | This error is caused by a cold solder joint under the Southbridge or the ethernet chip. In rare cases it can also be triggered by a cold joint under the GPU on one of the lines that run to the Southbridge chip. Missing parts(caps, resistors…) under the Southbridge can trigger this error as well. |
E74 | 1022 | Cold solder joint under GPU- (H)ANA | If you soldered anything to the mainboard before it occurred, whatever you are powering from this point is drawing too much power so get rid of it.Also get rid of everything that you can see that might bridge anything near the GPU. Tighten the GPU screws facing the HANA chip slightly more and make sure to be using a shim. Adding an extra shim on each side of the smaller chip dye will help to create more surface against the heatsink and will increase the chances of the error going away for good. If there is a lot of flexing under the GPU, bake the board to unflex it. Reflow the GPU and HANA chip. | This error is caused by a cold solder joint under the GPU, (H)ANA-chip or in between. Mostly it is one of the outer solder balls on the side facing the (H)ANA chip so a shim increases the chanced of success quite a bit. Can also be a component that is missing or damaged so look for missing parts near the GPU and the (H)ANA chip. |
E75 | 1023 | Network chip cold joint / wrong vendor | Connect the DVD drive and check if the error code is still the same… Remove everything you might have soldered to this area. Reflow the Southbridge and Network chip. Replace the Network chip. | This error is related to the network chip, might be power related or so.This can happen while installing and NME 2. In general it sounds like a cold solder joint somewhere there.However it can also be a Hitachi DVD drive that is not connected… Couldn’t read ethernet phy vendor/wrong ethernet vendor. |
E76 | 1030 | Dead network chip | Replace the Network chip. Connect the DVD drive and check if the error code is still the same. Remove everything you might have soldered to this area. Reflow the Southbridge and Network chip. | This error is caused by a dead network chip. This can happen when lightning hits your house and the network chip is under high voltage. Couldn’t complete ethernet reset. |
E77 | 1031 | Dead network chip | Replace the Network chip and other damaged components around it like blown capacitors defective regulators etc. Also reflowing Southbridge and Network chip can help | This error is caused by a dead network chip. It can occur when your house gets hit in a thunderstorm… phy request is already processing/ reading reg failed/ Failed to write reg. |
E78 | 1032 | AsicId check failed | N/A | AsicId check failed |
E79 | 1033 | Broken hard drive (Xam.xex) | Replace hard drive. Try Southbridge X-Clamp fix and reflow Southbridge. Check JTAG wiring! Especially the diodes they MUST face the correct direction - Away from J2D2. | This error occurs when your hard drive is defective, it might still work sometimes…. There is also a small chance that it is a cold joint under the Southbridge causing problems with the I/O of the HDD. It can also be related to wiring the diodes while JTAGing. Couldn’t start xam.xex. |
E80 | 1100 | NAND - Wrong LDV Version | Downgrade to the old dashboard, solder the resistor back on and then update your Xbox. If you have the CPU Key, get the current NAND Flash image and fix the LDV (Just add 1 up to latest kernel). | Wrong LDV version in NAND Flash. You have the new dashboard update but not the resistor R3T6, follow known fixes to see how to resolve the problem. |
2 Red Lights
E-Code | Secondary | Description | Fixes | Detailed Description |
E05 | 0011 | The CPU is overheating | Make sure the CPU heatsink is making good contact with the chip, apply a thin layer of compound and put the heatsink on without screws, make sure it gives a good imprint then. Replace CPU X-Clamps, apply new thermal compound. It is possible to cut the temperature sensor trace, but is not recommended. | This error appears when the CPU overheated, after that the Xbox locks itself until it cooled the chip down. The reason for that is that the heat cant be dissipated to the heatsink/the heatsink isn’t cooled properly… This can be the result of improper thermal compound usage or if the error comes up instantly while booting the console, the heatsink will likely not be making any contact at all with the chip. In rare cases it can also be a faulty temp sensor. |
E06 | 0012 | The GPU is overheating | Make sure the GPU heatsink is making good contact with the chip, apply a thin layer of compound and put the heatsink on without screws, make sure it gives a good imprint then. Replace GPU X-Clamps and apply new thermal compound. It can also be fixed sometimes by just a slight tightening the GPU bolts, (1/4 or 1/8 turn). | This error appears when the GPU overheated, after that the Xbox locks itself until it cooled the chip down. The reason for that is that the heat cant be dissipated to the heatsink/ the heatsink isn’t cooled properly… This can be the result of improper thermal compound usage or if the error comes up instantly while booting the console, the heatsink will likely not be making any contact at all with the chip. |
E07 | 0013 | Cold joint under RAM/RAM overheating | Putting the faulty RAM brick under pressure with a 3mm thick craft foam pad. Reflow the RAM chips. A hybrid X-Clamp fix may help. | In 99% of the cases it is a cold solder joint under one of the RAM bricks though. It is also said to be an indicator for RAM overheating but this is extremely rare. This error may also be caused by cold solder joint under the HANA chip (Not Confirmed). 2 RAM bricks under the GPU heatsink cause the error 99% of the time. |
2 Red and 2 Green Lights
E-Code | Secondary | Description | Fixes | Detailed Description |
E48 | 0300 | MFG-Mode: Connection Failed | Reflow Southbridge and/or Restore NAND | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. |
E49 | 0301 | MFG-Mode: Gateway Connect/ NAND Corrupt/Blank | Replace RF board, Reflow Southbridge, and/or Restore NAND | This error can be caused by a faulty RF board and is indicated by 2 green and 2 red lights which swap every few seconds. It shows that when the console is in manufacturing mode as well, there are rumors that Microsoft does that to modded consoles that were sent in for repairs. It can also occur after an improper NAND update. When the Ethernet cable is connected it also shows E49 on the screen which means that it couldn’t connect to the gateway server in the factory. Single Red Light Takes About 6 Minutes To Show Up. |
E50 | 0302 | MFG-Mode: ConnectX cant be loaded | Reflow southbridge and/or Restore NAND | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. |
E51 | 0303 | MFG-Mode: Gateway IP not found | Reflow Southbridge and/or Restore NAND | This error is caused by a problem with the NAND content it might be corrupted and needs to be corrected. This error specifically means that the Console cannot find the IP-address of the Gateway. |
E52 | 0310 | MFG-Mode: Unable to parse the host response | Reflow Southbridge and/or Restore NAND | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. Could also be problem with Base64 encoding when sending commands. |
E53 | 0311 | MFG-Mode: Response submitted (factory command) | Reflow Southbridge and/or Restore NAND | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. |
E54 | 0312 | MFG-Mode: Problem setting keys | Reflow Southbridge and/or Restore NAND | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. |
E55 | 0313 | MFG-Mode: Phy Mfgbootlauncher fail? | Reflow Southbridge and/or Restore NAND | It shows that when the console is in manufacturing mode, theoretically it can also be a Southbridge issue so reflowing might work. More likely is an improper NAND update though, so a software related problem. |
3 Red Lights
E-Code | Secondary | Description | Fixes | Detailed Description |
E00 | 0000 | Xbox freezes after showing the first digit of the error code | Remove the dust from under Southbridge and HANA chip. Reflow Southbridge. X-Clamp replacement. | The Xbox doesn’t know what’s wrong it freezes after showing the first digit(0) of the error code. Might be a cold solder joint somewhere under the GPU as someone fixed it with the X-Clamp replacement, might also be scaler or Southbridge related since this is where the error code is calculated… It can also be caused by dust under the Southbridge and the HANA chip so please check for that… |
E01 | 0001 | Short circuit in the console/faulty PSU | Make sure your PSU is working and replace it if it isn’t. Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that move out of place while using a heatgun, etc. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU, HANA chip. X-Clamp replacement. | This error can be triggered by a faulty power supply or a short in the console. The short is located near one of the main supply lines, so mostly not under the chips, it might also be a blown capacitor fuse or just a bridged contact. Also damaged DVD power cable. The GPU heatsink might be shorting out if you screwed it in too tight. |
E02 | 0002 | Cold solder joint under CPU | Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that moved out of place while reflowing, etc. - Especially in the CPU area. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU. X-Clamp replacement. | This error code is caused by a cold solder joint under the CPU or by a problem with the way it is powered(blown MOSFET, capacitor or a short). It may also be a problem with the ethernet chip but there aren’t any references for that. |
E03 | 0003 | Power problem/ Cold solder joint under CPU | Scan the mainboard and make sure that there is nothing that might short something out, like metal chipping, components, that moved out of place while reflowing, etc. - Especially in the CPU area. Replace MOSFETs and regulators that are known to cause it if they were blown. Check if the standby voltages are existent, if they are not at a certain area replace the parts in the area which are likely to be defective. Reflow the CPU. X-Clamp replacement. | The CPU is somehow not getting clean power, can be a cold solder joint under it or one of the external parts like a missing cap etc. |
E04 | 0010 | Cold solder joint under Southbridge OR bad RF board | Try another RF board. If LEDs were modded, try removing them. Southbridge X-Clamp replacement. Southbridge reflow. Check the are under the Southbridge for parts that might have fallen off and solder them back on. | There is a problem with the Southbridge Chip usually dealing with how it connects to the mainboard (cold solder joint/bridged solder joints)(Taken from Xbox-Scene) |
E08 | 0020 | Bridged solder joint/short - CPU/GPU/RAM | If you worked on the mainboard recently(soldered or so) remove these wires because you might be drawing too much power from the GPU. Also look for missing/bridged components like capacitors/resistors. If you JTAG hacked the console, remove wires and resistors, the parallel port can stay as long as no PC is connected. X-Clamp replacement. Flush with alcohol, let dry, begin reflow with flux like below. Reflow GPU and RAM area. Reball GPU and RAM for bridged solder. | This error is caused by a bridged solder joint under CPU, GPU or one of the RAM bricks. This effect can also be caused by tin whiskers leading to shorts and if the GPU was taken off the mainboard this error will also show up. It can also be power related(the CPU/GPU or RAM isn’t getting enough power). Can also be a component that is missing or damaged so look for missing and bridged parts near the GPU. If the console was JTAGged and the resistors and cables are still connected it will show 0020, the parallel port can stay as long as no PC is connected. |
E09 | 0021 | Bridged solder joint/Short - GPU/Southbridge | If you worked on the mainboard recently(soldered or so) remove these wires because you might be drawing too much power from the Southbridge. Also look for missing/bridged components like capacitors/resistors. X-Clamp replacement. Southbridge X-Clamp fix. Reflow Southbridge/Ethernet chip area. Reball the Southbridge - bridged solder. If you work in dumping lite-on 8xxxx and 9xxxx with jumper, Check your DVD drive motherboard again, if there’s still some shorting. Wrong GPU model (e.g. Zephyr/Falcon GPU reballed onto a Xenon board). | This error is caused by a bridged solder joint under GPU or Southbridge. It can also be power related(the Southbridge isn’t getting enough power). Can also be a component that is missing or damaged so look for missing and bridged parts(caps etc) near the Southbridge. |
E10 | 0022 | Bridged solder joint/Short GPU-> (H)ANA | If you soldered anything to the mainboard before it occurred, whatever you are powering from this point is drawing too much power so get rid of it.Also get rid of everything that you can see that might bridge anything near the GPU. X-Clamp replacement. Reflow GPU and HANA chip. Reflow GPU and HANA chip. Reflow CPU. If using JTAG on JTAG-fixed Xbox 360 this will appear, flash to original NAND. Can be caused by broken trace. | This error is caused by a bridged/shorting solder joint under the GPU, (H)ANA-chip or in between. It can also be power related though, for example if you are drawing power from one of the regulators that power the GPU and HANA-chip. Can also be a component that is missing or damaged so look for missing parts near the GPU and the HANA chip. In extremely rare cases it might also be related to the lines that lead from HANA to the CPU. The chances are however higher that it is the GPU than the HANA chip so you should always first concentrate on the GPU. Another cause could be due to a broken trace under the board near one of the RAM blocks (picture). This error also shows up if the CPU was taken off the mainboard. |
E11 | 0023 | (unknown) probably a short under Southbridge>ANA | N/A | This error is unknown but assumed to be a short either under Southbridge and (H)ANA chip or in between these. Look for 0021 and 0022 and reflow the Southbridge-> HANA chip area, the X-Clamp Fix might help as well. |
E12 | 0030 | Temp sensor problem/ Cold solder joint under CPU | Replace X-Clamps. Reflow CPU. Cut CPU temp sensor trace (NOT RECOMMENDED!) | The temp sensor is not working properly, maybe because it is shorting out (2 bridged solder balls). If it’s completely broken, you may need to cut the trace anyway. |
E13 | 0031 | Faulty RAM brick/ Shorted out resistor | Reflow RAM and Southbridge. Loosen heatsink screws and make sure heatsink isn’t shorting out a capacitor. Replace faulty RAM brick. X-Clamp replacement. Replace DVD power cord. Unbridged U6T1 or U6T2(points that protect CPU-fuse) | This error is caused by a faulty/cracked RAM brick, however it can also be caused when the heatsink is shorting out a resistor or like a bad solder joint under the GPU?, check out the links in the references… Also caused by the Southbridge if not properly soldered to motherboard or if it experiences a power short. Can be caused by a backwards power cord or faulty power cord to DVD player. If you update to freeboot 9199 with bridged U6T1 or U6T2 this error will appear, unbridged it. |
E14 | 0032 | (unknown) probably temp sensor related | N/A | Might be temp sensor related, check out 0030 |
E15 | 0033 | (unknown) probably temp sensor related | N/A | Might be temp sensor related, check out 0030 |
E16 | 0100 | Cold solder joint - GPU | X-Clamp Replacement. Reflow GPU. | This error is a Cold solder joint under the GPU just like 0102, can be fixed with the X-Clamp replacement. |
E17 | 0101 | USB port (bridged pins) | Unplug all USB devices that might be connected to your 360. Remove solder from the pins under the USB ports so that they are not shorting out anymore, also check the ports themselves and make sure that the pins inside aren’t bridging. | This error is caused by bridged solder joints under the USB ports or a defective USB device that is connected to it. |
E18 | 0102 | Cold solder joint - CPU/GPU/RAM | X-Clamp replacement. Reflow GPU and RAM. | This error is caused by a cold solder joint under CPU, GPU or one of the RAM bricks. Can also be a component that is missing or damaged so look for missing parts near the GPU. |
E19 | 0103 | Cold solder joint- GPU/ bad cap | Remove short circuit from bridged capacitor under the GPU. X-Clamp replacement. Reflow CPU/GPU/RAM. | This error can either be caused by a cold solder joint under the GPU or a bridged capacitor under it(power problem). |
E20 | 0110 | Cold solder joint -> RAM | Reflow the RAM. Loosen your heatsink screws and make sure the heatsink isn’t shorting out a capacitor. Look for missing and bridged components like resisitors and caps and replace them. X-Clamp replacement. | This error is caused by a cold solder joint under one of the RAM chips, mostly its the top ones, sometimes it can also be one of the solder balls under the GPU that lead to the RAM. It can also be cause by a broken trace that connects the GPU and the RAM, the reason for it to break could be the flexing in this certain area. |
E21 | 0111 | (unknown) probably NAND/RAM? | N/A | This error is unknown but could be somehow related to a cold solder joint under the RAM.On Xbox-scene there was also a post in which was claimed that it has to do with the NAND. |
E22 | 0112 | (unknown) probably RAM | N/A | This error is totally unknown, probably it is RAM related like 0110. |
E23 | 0113 | (unknown) probably RAM | N/A | This error is totally unknown, probably it is RAM related like 0110. |
E24 | 0120 | (unknown) short under RAM | Penny fix on RAM | This error is unknown but someone on Xbox-scene could fix it using the penny fix.Could be a short in the area under the RAM that causes 0110 when there is a cold solder joint. If it was like usual the error code would be 0020. |
E25 | 0121 | Cold solder joint under CPU | Replacing the X-Clamps. Reflowing CPU. | Cold solder joint under CPU. The CPU cant communicate with the mainboard. |
E27 | 0123 | (unknown) | N/A | The error is completely unknown |
E28 | 0130 | (unknown) | N/A | The error is completely unknown |
E29 | 0131 | (unknown) | N/A | The error is completely unknown |
E30 | 0132 | (unknown) | N/A | The error is completely unknown |
E31 | 0133 | (unknown) | N/A | The error is completely unknown |
E32 | 0200 | Cold solder joint GPU/RAM | Reflow the GPU/RAM and flush them with alcohol. X-Clamp Fix. | This error is caused by a Cold Joint in the GPU/RAM area similar to 0102 good results could be achieved with flushing alcohol under the chips, reflowing them and afterwards applying an X-Clamp Fix. |
E33 | 0201 | Cold solder joint-> GPU/RAM | N/A | The error is very rare but it is somehow GPU/RAM related, two people could fix it with the Improved X-Clamp replacement, one had to remove his washers from the RAM in order to get it to work. |
E34 | 0202 | (unknown) | N/A | The error is completely unknown |
E35 | 0203 | GPU related - resistors | N/A | code 0203 - instant RROD every time. chip malfunction, not getting a connection to the board (not an overheating problem but a bad contact problem) mine turned out to be broken prongs in a corner on the GPU, missing 3 of them. didn’t see this until i was comparing with another board. i believe these are mini resistors on the bottom side of the chip due to mistreatment. |
E36 | 0210 | (unknown) | N/A | This error is completely unknown |
E37 | 0211 | (unknown) | N/A | This error is completely unknown |
E38 | 0212 | (unknown) | N/A | This error is completely unknown |
E39 | 0213 | (unknown) | N/A | This error is completely unknown |
E40 | 0220 | (unknown) missing resistors GPU | N/A | This error is unknown but is assumed to be caused by missing resistors, probably on GPU. |
E41 | 0221 | (unknown) | N/A | This error is completely unknown. |
E42 | 0222 | (unknown) GPU/CPU related? | X-Clamp replacement. | This error is unknown but someone managed to fix it using the X-Clamp replacement. |
E43 | 0223 | (unknown) | N/A | This error is completely unknown. |
E44 | 0230 | (unknown) | N/A | This error is completely unknown. |
E45 | 0231 | (unknown) | N/A | This error is completely unknown. |
E46 | 0232 | DVD Drive Failure | Fixed by Microsoft (unconfirmed) | “The DVD drive overheats. This error can be caused by the disconnecting of the DVD drive. This is usually not the case.” (unconfirmed) |
E47 | 0233 | (unknown) | N/A | This error is completely unknown. |
E56 | 0320 | (unknown) | N/A | This error is completely unknown. |
E57 | 0321 | (unknown) | N/A | This error is completely unknown. |
E58 | 0322 | (unknown) | N/A | This error is completely unknown. |
E59 | 0323 | (unknown) | N/A | This error is completely unknown. |
E60 | 0330 | (unknown) | N/A | This error is completely unknown. |
E61 | 0331 | (unknown) | N/A | This error is completely unknown. |
E62 | 0332 | (unknown) | N/A | This error is completely unknown. |
E63 | 0333 | (unknown) | N/A | This error is completely unknown. |
4 Red Lights
E-Code | Secondary | Description | Fixes | Detailed Description |
---|---|---|---|---|
N/A | 4444 | Faulty/Missing A/V cable or (H)ANA related | N/A | N/A |
Secondary Error Codes
A secondary error code can be obtained through a button combination to provide more insight on the issue the Xbox 360 is experiencing. To determine which error message corresponds to your secondary error code, consult the secondary error code list provided by Xbox-Experts.
- Power the console on so the red lights are flashing.
- Press and hold the small white Sync button and press the Eject button.
- The LEDs will now blink the first number in the code (see number table below).
- Release the eject button and press it again.
- The LEDs will now blink the second number of the code.
- Release the eject button and press it again.
- The LEDs will now blink the third number of the code.
- Release the eject button and press it again.
- The LEDs will now blink the forth number of the code.
- Release the eject button and press it again.
- The LEDs will go back to the 3 red flashing lights.
You should be able to determine the difference between the 3 flashing lights and the error code lights by the rate in which they flash.
Number of Lights Flashing | Error Digit |
---|---|
Four | 0 |
One | 1 |
Two | 2 |
Three | 3 |