CRT:PVM-14L4
Jump to navigation
Jump to search
PVM-14L4
Information | ||
---|---|---|
Manufacturer | Sony | |
Type | Professional | |
Size | 14" | |
TV Lines | 800 (4:3), 600 (16:9) | |
Dot Pitch | 0.25mm | |
Regions | NTSC, PAL, SECAM | |
240p/480i | Yes | |
480p | No | |
720p | No | |
1080i | No | |
Vsync | 50/60hz | |
Widescreen | No | |
Composite | 2x (Line A/B) | |
S-Video | 1x (Line A) | |
Component | 1x RGB/YPbPr | |
SDI | 0 | |
Dimensions | Width: 346mm
Depth: 424mm Height: 280mm | |
Weight | 37.5lb, 17kg | |
Firmware | Unknown | |
Links | ||
Standard Boards | None | |
Optional Boards | CRT:BKM-120D CRT:BKM-155DV | |
Operation Manual | PVM-14L4 Manual | |
Brochure | PVM-14L4 Brochure |
The BVM-D and PVM-L series monitors require a rather rare input board for RGB/YPbPr inputs: the CRT:BKM-129X. It is recommended to instead get Martin Hejnfelt's BKM-129X clone (source files) as it is much cheaper and built with modern parts.
Technical Bulletins
If you'd like to help out, please open each document below and edit the document's page to change "(unknown)" to a small description of what the bulletin is about.
When all of the documents are identified, please remove this warning.
When all of the documents are identified, please remove this warning.
File Name | Purpose |
---|---|
File:302002174.pdf | Fix: The unit may not power-on if the +5V bus for the CPU and signal circuit does not start. |
File:302003004.pdf | Firmware Error on M-Board causes video fault with SDI on a BKM-150CP. |
File:302003096.pdf | Fix: Replace a cap to eliminate noise on V.SYNC line when using H/V delay feature. |
File:302003099.pdf | Fix: Introduce a ferrite core if video is randomly missing on top of the picture |
File:302003164.pdf | Compatibility listing of B, T and M Board combinations. |
File:302003186.pdf | Restoring compatibility between older/newer T and Q boards |
File:302003188.pdf | Fix: No/dark picture - heater IC may be damaged. |
File:302004039.pdf | Fix: The monitor may not power-on if a component part on the G board (such as Q606, Q617, Q618, IC602) fails. |
File:302004077.pdf | Instructions for G2 and white balance adjustment |
File:302004080.pdf | Information about incomplete white balance adjustment after replacing the CRT |
File:302009150.pdf | Parts registration: Brackets and tightening band holder |