CRT:PVM-20L4
Jump to navigation
Jump to search
PVM-20L4
Information | ||
---|---|---|
Manufacturer | Sony | |
Type | Professional | |
Size | 20" | |
TV Lines | 800 (4:3), 600 (16:9) | |
Dot Pitch | 0.31mm | |
Regions | NTSC, PAL, SECAM | |
240p/480i | Yes | |
480p | No | |
720p | No | |
1080i | No | |
Vsync | 50/60hz | |
Widescreen | No | |
Composite | 2x (Line A/B) | |
S-Video | 1x (Line A) | |
Component | 1x RGB/YPbPr | |
SDI | 0 | |
Dimensions | Width: 452mm
Depth: 500mm Height: 414mm | |
Weight | 68.3lb, 31kg | |
Firmware | Unknown | |
Links | ||
Standard Boards | None | |
Optional Boards | CRT:BKM-120D CRT:BKM-155DV | |
Operation Manual | PVM-20L4 Manual | |
Brochure | PVM-20L4 Brochure |
The BVM-D and PVM-L series monitors require a rather rare input board for RGB/YPbPr inputs: the CRT:BKM-129X. It is recommended to instead get Martin Hejnfelt's BKM-129X clone (source files) as it is much cheaper and built with modern parts.
Technical Bulletins
If you'd like to help out, please open each document below and edit the document's page to change "(unknown)" to a small description of what the bulletin is about.
When all of the documents are identified, please remove this warning.
When all of the documents are identified, please remove this warning.
File Name | Purpose |
---|---|
File:302002174.pdf | Fix: The unit may not power-on if the +5V bus for the CPU and signal circuit does not start. |
File:302003004.pdf | Firmware Error on M-Board causes video fault with SDI on a BKM-150CP. |
File:302003096.pdf | Fix: Replace a cap to eliminate noise on V.SYNC line when using H/V delay feature. |
File:302003099.pdf | Fix: Introduce a ferrite core if video is randomly missing on top of the picture |
File:302003164.pdf | Compatibility listing of B, T and M Board combinations |
File:302003186.pdf | Restoring compatibility between older/newer T and Q boards |
File:302003188.pdf | Fix: No/dark picture - heater IC may be damaged |
File:302004039.pdf | Fix: The monitor may not power-on if a component part on the G board (such as Q606, Q617, Q618, IC602) fails. |
File:302004077.pdf | Instructions for G2 and white balance adjustment |
File:302004080.pdf | Information about incomplete white balance adjustment after replacing the CRT |
File:302008107.pdf | Fix: Unit may not power on if the DY block overheats after servicing. |
File:302009150.pdf | Parts registration: Brackets and tightening band holder |
File:302003105.pdf | NO POWER WHEN USED WITH PVM-20L/14L MONITORS IN SERIAL REMOTE CONNECTION |
Related Documents
If you'd like to help out, please open each document below and edit the document's page to change "(unknown)" to a small description of what the document is about.
If Technical Bulletin is in this table, please move it to the Technical Bulletins table below. When all of the documents are identified, please remove this warning.
If Technical Bulletin is in this table, please move it to the Technical Bulletins table below. When all of the documents are identified, please remove this warning.
File Name | Purpose |
---|---|
File:BKM-120D.pdf | Installation Manual |
File:PVM-14L4PVM20L4PVM-14L3.pdf | Multi language Manual |