CRT:CRT Repair Guide: Difference between revisions

From ConsoleMods Wiki
Jump to navigation Jump to search
 
(3 intermediate revisions by the same user not shown)
Line 4: Line 4:
* Check solder joints of AC plug
* Check solder joints of AC plug
* Check voltages on board
* Check voltages on board
*:<youtube>R_ipSle034o</youtube>
 
<youtube>https://www.youtube.com/watch?v=R_ipSle034o</youtube>


== Vertical Deflection Collapse ==
== Vertical Deflection Collapse ==
Line 17: Line 18:


<youtube>XGuS2zFMZ8w</youtube>
<youtube>XGuS2zFMZ8w</youtube>


<youtube>_kgy7CCsEBQ</youtube>
<youtube>_kgy7CCsEBQ</youtube>
Line 22: Line 24:
== Internal Magnetic Interference ==
== Internal Magnetic Interference ==


While rare, it's possible that internal components can cause magnetism issues on the screen.
A CRT can be exposed to enough magnetic interference that the image retains a persistent color or geometry issue. Generally, these issues can be fixed by enough degaussings by the built-in degausser or by using a stronger external degausser coil. While rare, it's possible that internal components or the case shell can cause magnetism issues on the screen.


<youtube>SpGeq_vqTF4</youtube>
<youtube>SpGeq_vqTF4</youtube>

Latest revision as of 18:08, 8 October 2023

Power Issues

  • Check fuse
  • Check solder joints of AC plug
  • Check voltages on board

Vertical Deflection Collapse

Characteristic red/green/blue retrace lines visible on the screen.

Tube Rejuvenation

Last resort to bring back dim tubes, burns oxidation off of guns.


Internal Magnetic Interference

A CRT can be exposed to enough magnetic interference that the image retains a persistent color or geometry issue. Generally, these issues can be fixed by enough degaussings by the built-in degausser or by using a stronger external degausser coil. While rare, it's possible that internal components or the case shell can cause magnetism issues on the screen.