Intellivision:General Troubleshooting: Revision history

Jump to navigation Jump to search

Diff selection: Mark the radio buttons of the revisions to compare and hit enter or the button at the bottom.
Legend: (cur) = difference with latest revision, (prev) = difference with preceding revision, m = minor edit.

6 October 2024

  • curprev 23:1523:15, 6 October 2024Derf talk contribs 968 bytes +968 Created page with "If your Intellivision is having issues, check the below general troubleshooting information for help. == Black / Gray Screen == * Reflow cartridge port connections. * Ensure all voltages reach the main logic board (check ribbon cable connection, not just the power supply board). * For model 1, replace the two 3906 transistors near the CPU that often burn out. * Check Master Clock Signal: Use a frequency counter to verify the master clock signal at Pin 10 of the cartri..."