{{Warning|Do not ever put your console in the freezer or out in the cold/hot weather or wrap it in a towel. These "fixes" will cause bigger problems due to temperature shock, board warping, and condensation.}} | {{Warning|Do not ever put your console in the freezer or out in the cold/hot weather or wrap it in a towel. These "fixes" will cause bigger problems due to temperature shock, board warping, and condensation.}} | ||
This page is intended to be a comprehensive list of all error codes for all models of Xbox 360, as well as tutorials on fixing them if applicable/possible. This error code guide is in no way official and may not be 100% accurate as it is community sourced. '''We take no responsibility for any actions you may take to fix your console.''' | This page is intended to be a comprehensive list of all error codes for all models of Xbox 360, as well as tutorials on fixing them if applicable/possible. This error code guide is in no way official and may not be 100% accurate as it is community sourced. '''We take no responsibility for any actions you may take to fix your console.''' | ||
Line 8: | Line 8: | ||
Board is unresponsive to power button | Board is unresponsive to power button | ||
* [https:// | * [https://xenonlibrary.com/wiki/Repair_Actions/No_Power Detailed Diagnostic/Repair Actions] | ||
== Red Ring of Death == | == Red Ring of Death == | ||
Ring of light quadrants flashing red/center light red | Ring of light quadrants flashing red/center light red. | ||
* To diagnose, hold down the sync button and press eject 4 times | * To diagnose, hold down the sync button and press eject 4 times | ||
Line 31: | Line 31: | ||
|- | |- | ||
| '''0001''' || ERROR_V_12P0 || ANA_V12P0_PWRGD negated unexpectedly || Replace Power Supply, Check V_12P0 rail components | | '''0001''' || ERROR_V_12P0 || ANA_V12P0_PWRGD negated unexpectedly || Replace Power Supply, Check V_12P0 rail components | ||
[https://xenonlibrary.com/wiki/Repair_Actions/0001 Detailed Diagnostic/Repair Actions] | |||
|- | |- | ||
| '''0002''' || ERROR_V_CPUCORE || VREG_CPU_PWRGD negated unexpectedly || Replace Power Supply, Check V_CPUCORE rail components | | '''0002''' || ERROR_V_CPUCORE || VREG_CPU_PWRGD negated unexpectedly || Replace Power Supply, Check V_CPUCORE rail components | ||
[https://xenonlibrary.com/wiki/Repair_Actions/0002 Detailed Diagnostic/Repair Actions] | |||
|- | |- | ||
| '''0003<br><small>Phat</small>''' || ERROR_V_GPUCORE || VREG_GPU_PWRGD negated unexpectedly || Replace Power Supply, Check V_GPUCORE rail components | | '''0003<br><small>Phat</small>''' || ERROR_V_GPUCORE || VREG_GPU_PWRGD negated unexpectedly || Replace Power Supply, Check V_GPUCORE rail components | ||
[https://xenonlibrary.com/wiki/Repair_Actions/0003 Detailed Diagnostic/Repair Actions] | |||
|- | |- | ||
| '''0003<br><small>Slim</small>''' || ERROR_V_3P3 || VREG_V3P3_PWRGD negated unexpectedly || Replace Power Supply, Check V_3P3 rail components | | '''0003<br><small>Slim</small>''' || ERROR_V_3P3 || VREG_V3P3_PWRGD negated unexpectedly || Replace Power Supply, Check V_3P3 rail components | ||
[https://xenonlibrary.com/wiki/Repair_Actions/0001 Detailed Diagnostic/Repair Actions] | |||
|- | |- | ||
| '''0010''' || ERROR_NO_HANA/ERROR_NO_ANA || HANA/ANA is not responding to reads or writes || Replace HANA/ANA or Southbridge | | '''0010''' || ERROR_NO_HANA/ERROR_NO_ANA || HANA/ANA is not responding to reads or writes || Replace HANA/ANA or Southbridge | ||
|- | |- | ||
| '''0011''' || ERROR_THERMAL_CPU || CPU temperature overload || [https:// | | '''0011''' || ERROR_THERMAL_CPU || CPU temperature overload || rowspan="3" | [https://xenonlibrary.com/wiki/Repair_Actions/Thermal Detailed Diagnostic/Repair Actions] | ||
|- | |- | ||
| '''0012''' || ERROR_THERMAL_GPU || GPU temperature overload | | '''0012''' || ERROR_THERMAL_GPU || GPU temperature overload | ||
|- | |- | ||
| '''0013''' || ERROR_THERMAL_EDRAM || eDRAM temperature overload | | '''0013''' || ERROR_THERMAL_EDRAM || eDRAM temperature overload | ||
|- | |- | ||
| '''0020''' || ERROR_GPU_RST_DONE || GPU_RST_DONE signal missing after seqUnReset time passed || | | '''0020''' || ERROR_GPU_RST_DONE || GPU_RST_DONE signal missing after seqUnReset time passed || Check GPU clock, RST, RST_DONE circuits, Replace GPU | ||
|- | |- | ||
| '''0021''' || ERROR_NO_PCIE || PCIE link did not enter L0 after seqUnReset time passed || | | '''0021''' || ERROR_NO_PCIE || PCIE link did not enter L0 after seqUnReset time passed || Check PCIe and PCIe clock circuits, Replace GPU or Southbridge | ||
|- | |- | ||
| '''0022''' || ERROR_NO_HANDSHAKE || CPU did not send GetPowerUpCause to SMC || | | '''0022''' || ERROR_NO_HANDSHAKE || CPU did not send GetPowerUpCause to SMC || Check POST code, Check CPU clock, RST, and PLL circuits, Replace CPU | ||
|- | |- | ||
| '''0023<br><small>Phat</small>''' || ERROR_NO_CLOCKCHIP || Clockgen is not responding to reads or writes || Replace ANA_BCKUP (Xenon), ANA/HANA, or Southbridge | | '''0023<br><small>Phat</small>''' || ERROR_NO_CLOCKCHIP || Clockgen is not responding to reads or writes || Replace ANA_BCKUP (Xenon), ANA/HANA, or Southbridge | ||
Line 59: | Line 63: | ||
|- | |- | ||
| '''0031''' || ERROR_V_5P0 || VREG_V5P0_PWRGD negated unexpectedly || Replace Power Supply, Check V_5P0 rail components | | '''0031''' || ERROR_V_5P0 || VREG_V5P0_PWRGD negated unexpectedly || Replace Power Supply, Check V_5P0 rail components | ||
[https://xenonlibrary.com/wiki/Repair_Actions/0031 Detailed Diagnostic/Repair Actions] | |||
|- | |- | ||
| '''0032''' || ERROR_V_CPUVCS || VREG_CPUCORE_VCS_PWRGD negated unexpectedly || Replace Power Supply, Check V_CPUVCS rail components | | '''0032''' || ERROR_V_CPUVCS || VREG_CPUCORE_VCS_PWRGD negated unexpectedly || Replace Power Supply, Check V_CPUVCS rail components | ||
[https://xenonlibrary.com/wiki/Repair_Actions/0032 Detailed Diagnostic/Repair Actions] | |||
|- | |- | ||
| '''0033''' || ERROR_V_MEM || VREG_VMEM_PWRGD negated unexpectedly || Replace Power Supply, Check V_MEM rail components | | '''0033''' || ERROR_V_MEM || VREG_VMEM_PWRGD negated unexpectedly || Replace Power Supply, Check V_MEM rail components | ||
[https://xenonlibrary.com/wiki/Repair_Actions/0033 Detailed Diagnostic/Repair Actions] | |||
|} | |} | ||
=== Xbox System Software (XSS) Errors === | === Xbox System Software (XSS) Errors === | ||
{| class="wikitable" | {| class="wikitable" | ||
!Error Code | |||
!Name | |||
!Explanation | |||
!Possible Repair Actions | |||
|- | |- | ||
| '''0100'''|| ERROR_NBINIT_MEM_VENDOR_ID || RAM Vendor ID wrong, or not detected || rowspan="6" | Replace GPU or RAM | |||
|- | |- | ||
| ''' | | '''0101'''|| ERROR_NBINIT_MEM_READ_STROBE_DATA_WRITE || Could not write data for RAM read strobe training | ||
|- | |- | ||
| ''' | | '''0102''' || ERROR_NBINIT_MEM_READ_STROBE_DELAY_TRAINING || Memory read strobe delay training failed | ||
|- | |- | ||
| ''' | | '''0103''' || ERROR_NBINIT_MEM_WRITE_STROBE_DELAY_TRAINING|| Memory write strobe delay training failed | ||
|- | |- | ||
| ''' | | '''0110''' || ERROR_MEMORY_ADDRESSING || Memory address line failed or unresponsive | ||
|- | |- | ||
| ''' | | '''0111''' || ERROR_MEMORY_DATA || Memory data line failed or unresponsive | ||
|- | |- | ||
| | |} | ||
=== Xbox System Software (XSS) Errors with Universal Error Message (UEM) === | |||
{| class="wikitable" | |||
|- | |- | ||
! Error Code !! Name !! Explanation !! Possible Repair Actions | |||
|- | |- | ||
| '''1000<br>E 64''' || ERROR_XSS_CDROM_TIMED_OUT || Kernel DVD drive communications timed out || Replace SATA cable to DVD drive, replace DVD drive PCB, replace Southbridge | | '''1000<br>E 64''' || ERROR_XSS_CDROM_TIMED_OUT || Kernel DVD drive communications timed out || rowspan="3" | Replace SATA cable to DVD drive, replace DVD drive PCB, replace Southbridge | ||
|- | |- | ||
| '''1001<br>E 65''' || ERROR_XSS_CDROM_NOT_DMA_CONFIGURED || Kernel could not configure DVD drive for DMA mode | | '''1001<br>E 65''' || ERROR_XSS_CDROM_NOT_DMA_CONFIGURED || Kernel could not configure DVD drive for DMA mode | ||
|- | |- | ||
| '''1002<br>E 66''' || ERROR_XSS_CDROM_COULD_NOT_CREATE_DEVICE || Kernel could not create DVD drive instance | | '''1002<br>E 66''' || ERROR_XSS_CDROM_COULD_NOT_CREATE_DEVICE || Kernel could not create DVD drive instance | ||
|- | |- | ||
| '''1003<br>E 67''' || ERROR_XSS_HDD_TIMED_OUT || Kernel HDD communications timed out || Replace HDD, replace HDD port/cable, replace Southbridge | | '''1003<br>E 67''' || ERROR_XSS_HDD_TIMED_OUT || Kernel HDD communications timed out || rowspan="4" | Replace HDD, replace HDD port/cable, replace Southbridge | ||
|- | |- | ||
| '''1010<br>E 68''' || ERROR_XSS_HDD_NOT_DMA_CONFIGURED || Kernel could not configure HDD for DMA mode | | '''1010<br>E 68''' || ERROR_XSS_HDD_NOT_DMA_CONFIGURED || Kernel could not configure HDD for DMA mode | ||
|- | |- | ||
| '''1011<br>E 69''' || ERROR_XSS_HDD_COULD_NOT_CREATE_DEVICE || Kernel could not create HDD instance | | '''1011<br>E 69''' || ERROR_XSS_HDD_COULD_NOT_CREATE_DEVICE || Kernel could not create HDD instance | ||
|- | |- | ||
| '''1012<br>E 70''' || ERROR_XSS_HDD_NOT_FOUND || Kernel couldn't find HDD Note: This error does not show up because a HDD is missing, it shows up when a HDD is detected, but can't be found | | '''1012<br>E 70''' || ERROR_XSS_HDD_NOT_FOUND || Kernel couldn't find HDD Note: This error does not show up because a HDD is missing, it shows up when a HDD is detected, but can't be found | ||
|- | |- | ||
| '''1013<br>E 71''' || ERROR_XSS_XAM_NO_DASH || XAM could not find dash.xex on flash || Unplug HDD, if error clears, format or replace HDD, else Rebuild and reflash NAND | | '''1013<br>E 71''' || ERROR_XSS_XAM_NO_DASH || XAM could not find dash.xex on flash || Unplug HDD, if error clears, format or replace HDD, else [[Xbox 360:NAND Recovery using a Donor NAND|Rebuild and reflash NAND]] | ||
|- | |- | ||
| '''1020<br>E 72''' || ERROR_SMC_FLASH_CONFIG_CORRUPT || SMC configuration corrupt || Rebuild and reflash NAND | | '''1020<br>E 72''' || ERROR_SMC_FLASH_CONFIG_CORRUPT || SMC configuration corrupt || Rebuild and reflash NAND | ||
|- | |- | ||
| '''1021<br>E 73''' || ERROR_HSIO_TRAINING_FAILED || GPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive || Replace GPU | | '''1021<br>E 73''' || ERROR_HSIO_TRAINING_FAILED || GPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive || rowspan="2" | Replace GPU | ||
[https://xenonlibrary.com/wiki/Repair_Actions/HSIO Detailed Diagnostic/Repair Actions] | |||
|- | |- | ||
| '''1022<br>E 74''' || ERROR_HSIO_CALIBRATION_FAILED || GPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive | | '''1022<br>E 74''' || ERROR_HSIO_CALIBRATION_FAILED || GPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive | ||
|- | |- | ||
| '''1023<br>E 75''' || ERROR_UNEXPECTED_ETHERNET_PHY_VENDOR || Southbridge could not communicate with Ethernet PHY over MDIO/MDC || Replace Ethernet chip, replace Southbridge | | '''1023<br>E 75''' || ERROR_UNEXPECTED_ETHERNET_PHY_VENDOR || Southbridge could not communicate with Ethernet PHY over MDIO/MDC || Replace Ethernet chip, replace Southbridge | ||
|- | |- | ||
| '''1030<br>E 76''' || ERROR_ETHERNET_PHY_RESET_FAIL || Ethernet PHY failed to reset correctly or complete reset || Replace Ethernet chip | | '''1030<br>E 76''' || ERROR_ETHERNET_PHY_RESET_FAIL || Ethernet PHY failed to reset correctly or complete reset || rowspan="2" | Replace Ethernet chip | ||
|- | |- | ||
| '''1031<br>E 77''' || ERROR_ETHERNET_PHY_READ_WRITE_FAIL || Could not read or write to Ethernet PHY | | '''1031<br>E 77''' || ERROR_ETHERNET_PHY_READ_WRITE_FAIL || Could not read or write to Ethernet PHY | ||
|- | |- | ||
| '''1032<br>E 78''' || ERROR_UNSUPPORTED_GPU || GPU is down revision, not supported on this board || Replace GPU with correct revision for board | | '''1032<br>E 78''' || ERROR_UNSUPPORTED_GPU || GPU is down revision, not supported on this board || Replace GPU with correct revision for board | ||
|- | |- | ||
| '''1033<br>E 79''' || ERROR_XSS_FLASH_NO_XAM || xam.xex not found on flash || Unplug HDD, if error clears, format or replace HDD, else Rebuild and reflash NAND | | '''1033<br>E 79''' || ERROR_XSS_FLASH_NO_XAM || xam.xex not found on flash || Unplug HDD, if error clears, format or replace HDD, else [[Xbox 360:NAND Recovery using a Donor NAND|Rebuild and reflash NAND]] | ||
|- | |- | ||
| '''1100<br>E 80''' || Unknown || | | '''1100<br>E 80''' || Unknown || Mismatched LDV Version in the NAND Flash. Note: Last dashboard update probably failed. Related to eFuses. || If you are on an unmodded console and [[Xbox 360:Disabling the eFuse Burning Circuit|disabled eFuse Burning]] with the resistor removal method while on dashboard 12611 then you can solder a 10k ohm resistor where the old resistor was. | ||
|- | |- | ||
| '''1101<br>E 81''' || Unknown || XeKeysSecuritySaveSettings failed || Replace NAND | | '''1101<br>E 81''' || Unknown || XeKeysSecuritySaveSettings failed || Replace NAND | ||
|- | |- | ||
| '''1102<br>E 82''' || ERROR_HSIO_CALIBRATION_FAILED || CGPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive || Replace CGPU | | '''1102<br>E 82''' || ERROR_HSIO_CALIBRATION_FAILED || CGPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive || Replace CGPU | ||
[https://xenonlibrary.com/wiki/Repair_Actions/HSIO Detailed Diagnostic/Repair Actions] | |||
|} | |} | ||
==References== | ==References== | ||
* [https:// | * [https://xenonlibrary.com/wiki/Errors XenonLibrary Wikipage for Xbox 360 Errors] (info from leaked documentation and reverse engineering) |
Latest revision as of 19:22, 7 September 2024
Do not ever put your console in the freezer or out in the cold/hot weather or wrap it in a towel. These "fixes" will cause bigger problems due to temperature shock, board warping, and condensation. |
This page is intended to be a comprehensive list of all error codes for all models of Xbox 360, as well as tutorials on fixing them if applicable/possible. This error code guide is in no way official and may not be 100% accurate as it is community sourced. We take no responsibility for any actions you may take to fix your console.
Generally, if there is a problem with the Xbox 360, the LEDs in the Ring of Light (ROL) around the power button will flash in a particular pattern. The pattern itself lends some insight to the problem. Certain patterns will also display numbered error codes on screen, known as your primary error code, which will further help diagnose your console’s issue.
No Power
Board is unresponsive to power button
Red Ring of Death
Ring of light quadrants flashing red/center light red.
- To diagnose, hold down the sync button and press eject 4 times
- Each time you press eject, a certain number of the quadrants of the ring will flash
- 4 lights signify 0
- 1 lights signify 1
- 2 lights signify 2
- 3 lights signify 3
- On Xbox 360 E consoles, the ring will flash an amount of times then pause, count these to get the numbers
- After pressing it 4 times, you will have the secondary error code
- Example: seeing 4 lights 3 times, followed by 1 light once, means you have error code: 0001
System Management Controller (SMC) Errors
Error Code | Name | Explanation | Possible Repair Actions |
---|---|---|---|
0001 | ERROR_V_12P0 | ANA_V12P0_PWRGD negated unexpectedly | Replace Power Supply, Check V_12P0 rail components |
0002 | ERROR_V_CPUCORE | VREG_CPU_PWRGD negated unexpectedly | Replace Power Supply, Check V_CPUCORE rail components |
0003 Phat |
ERROR_V_GPUCORE | VREG_GPU_PWRGD negated unexpectedly | Replace Power Supply, Check V_GPUCORE rail components |
0003 Slim |
ERROR_V_3P3 | VREG_V3P3_PWRGD negated unexpectedly | Replace Power Supply, Check V_3P3 rail components |
0010 | ERROR_NO_HANA/ERROR_NO_ANA | HANA/ANA is not responding to reads or writes | Replace HANA/ANA or Southbridge |
0011 | ERROR_THERMAL_CPU | CPU temperature overload | Detailed Diagnostic/Repair Actions |
0012 | ERROR_THERMAL_GPU | GPU temperature overload | |
0013 | ERROR_THERMAL_EDRAM | eDRAM temperature overload | |
0020 | ERROR_GPU_RST_DONE | GPU_RST_DONE signal missing after seqUnReset time passed | Check GPU clock, RST, RST_DONE circuits, Replace GPU |
0021 | ERROR_NO_PCIE | PCIE link did not enter L0 after seqUnReset time passed | Check PCIe and PCIe clock circuits, Replace GPU or Southbridge |
0022 | ERROR_NO_HANDSHAKE | CPU did not send GetPowerUpCause to SMC | Check POST code, Check CPU clock, RST, and PLL circuits, Replace CPU |
0023 Phat |
ERROR_NO_CLOCKCHIP | Clockgen is not responding to reads or writes | Replace ANA_BCKUP (Xenon), ANA/HANA, or Southbridge |
0023 Slim |
ERROR_V_CPUEDRAM | VREG_VEDRAM_PWRGD negated unexpectedly | Replace Power Supply, Check V_CPUEDRAM rail components |
0030 | ERROR_NO_TEMPERATURES | HANA/ANA temperature registers read as zero | Check for shorted resistors, replace HANA/ANA |
0031 | ERROR_V_5P0 | VREG_V5P0_PWRGD negated unexpectedly | Replace Power Supply, Check V_5P0 rail components |
0032 | ERROR_V_CPUVCS | VREG_CPUCORE_VCS_PWRGD negated unexpectedly | Replace Power Supply, Check V_CPUVCS rail components |
0033 | ERROR_V_MEM | VREG_VMEM_PWRGD negated unexpectedly | Replace Power Supply, Check V_MEM rail components |
Xbox System Software (XSS) Errors
Error Code | Name | Explanation | Possible Repair Actions |
---|---|---|---|
0100 | ERROR_NBINIT_MEM_VENDOR_ID | RAM Vendor ID wrong, or not detected | Replace GPU or RAM |
0101 | ERROR_NBINIT_MEM_READ_STROBE_DATA_WRITE | Could not write data for RAM read strobe training | |
0102 | ERROR_NBINIT_MEM_READ_STROBE_DELAY_TRAINING | Memory read strobe delay training failed | |
0103 | ERROR_NBINIT_MEM_WRITE_STROBE_DELAY_TRAINING | Memory write strobe delay training failed | |
0110 | ERROR_MEMORY_ADDRESSING | Memory address line failed or unresponsive | |
0111 | ERROR_MEMORY_DATA | Memory data line failed or unresponsive |
Xbox System Software (XSS) Errors with Universal Error Message (UEM)
Error Code | Name | Explanation | Possible Repair Actions |
---|---|---|---|
1000 E 64 |
ERROR_XSS_CDROM_TIMED_OUT | Kernel DVD drive communications timed out | Replace SATA cable to DVD drive, replace DVD drive PCB, replace Southbridge |
1001 E 65 |
ERROR_XSS_CDROM_NOT_DMA_CONFIGURED | Kernel could not configure DVD drive for DMA mode | |
1002 E 66 |
ERROR_XSS_CDROM_COULD_NOT_CREATE_DEVICE | Kernel could not create DVD drive instance | |
1003 E 67 |
ERROR_XSS_HDD_TIMED_OUT | Kernel HDD communications timed out | Replace HDD, replace HDD port/cable, replace Southbridge |
1010 E 68 |
ERROR_XSS_HDD_NOT_DMA_CONFIGURED | Kernel could not configure HDD for DMA mode | |
1011 E 69 |
ERROR_XSS_HDD_COULD_NOT_CREATE_DEVICE | Kernel could not create HDD instance | |
1012 E 70 |
ERROR_XSS_HDD_NOT_FOUND | Kernel couldn't find HDD Note: This error does not show up because a HDD is missing, it shows up when a HDD is detected, but can't be found | |
1013 E 71 |
ERROR_XSS_XAM_NO_DASH | XAM could not find dash.xex on flash | Unplug HDD, if error clears, format or replace HDD, else Rebuild and reflash NAND |
1020 E 72 |
ERROR_SMC_FLASH_CONFIG_CORRUPT | SMC configuration corrupt | Rebuild and reflash NAND |
1021 E 73 |
ERROR_HSIO_TRAINING_FAILED | GPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive | Replace GPU |
1022 E 74 |
ERROR_HSIO_CALIBRATION_FAILED | GPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive | |
1023 E 75 |
ERROR_UNEXPECTED_ETHERNET_PHY_VENDOR | Southbridge could not communicate with Ethernet PHY over MDIO/MDC | Replace Ethernet chip, replace Southbridge |
1030 E 76 |
ERROR_ETHERNET_PHY_RESET_FAIL | Ethernet PHY failed to reset correctly or complete reset | Replace Ethernet chip |
1031 E 77 |
ERROR_ETHERNET_PHY_READ_WRITE_FAIL | Could not read or write to Ethernet PHY | |
1032 E 78 |
ERROR_UNSUPPORTED_GPU | GPU is down revision, not supported on this board | Replace GPU with correct revision for board |
1033 E 79 |
ERROR_XSS_FLASH_NO_XAM | xam.xex not found on flash | Unplug HDD, if error clears, format or replace HDD, else Rebuild and reflash NAND |
1100 E 80 |
Unknown | Mismatched LDV Version in the NAND Flash. Note: Last dashboard update probably failed. Related to eFuses. | If you are on an unmodded console and disabled eFuse Burning with the resistor removal method while on dashboard 12611 then you can solder a 10k ohm resistor where the old resistor was. |
1101 E 81 |
Unknown | XeKeysSecuritySaveSettings failed | Replace NAND |
1102 E 82 |
ERROR_HSIO_CALIBRATION_FAILED | CGPU to eDRAM High Speed Link failed, eDRAM faulty or unresponsive | Replace CGPU |